INSTALLATION INSTRUCTIONS
E-LSN05B-4U
FCC NOTICE
CAUTION: Changes or modifications not expressly approved
could void your authority to use this equipment.
This device complies with part 15 of the FCC Rules. Operation
is subject to the following two conditions: (1) This device may
not cause harmful interference, and (2) this device must accept
any interference received, including interference that may cause
undesired operation.
Changes or modifications not expressly approved could void
your authority to use this equipment.
This equipment has been tested and found to comply with the
limits for a Class B digital device, pursuant to part 15 of the
FCC Rules. These limits are designed to provide reasonable
protection against harmful interference in a residential
installation. This equipment generates, uses and can radiate
radio frequency energy and, if not installed and used in
accordance with the instructions, may cause harmful interference
to radio communications. However, there is no guarantee that
interference will not occur in a particular installation. If this
equipment does cause harmful interference to radio or television
reception, which can be determined by turning the equipment off
and on, the user is encouraged to try to correct the interference
by one or more of the following measures:
—Reorient or relocate the receiving antenna.
—Increase the separation between the equipment and receiver.
—Connect the equipment into an outlet on a circuit different from
that to which the receiver is connected.
—Consult the dealer or an experienced radio/TV technician for
help.
CAN ICES-005 (B)/NMB-005 (B)
www.e-conolight.com
|
Document:
Created By:
ELECTRICAL CONNECTIONS
Make the following Electrical Connections:
a. Connect the black fixture lead to the voltage supply lead (Hot
1 for 208/240V wiring)..
b. Connect the white fixture lead to the neutral supply lead (Hot
2 for 208/240V wiring).
c. Connect the green or green/yellow ground lead to the supply
ground lead.
d. If 0/1-10V Dimming is used, connect the violet fixture lead to
the supply positive dimming lead. For dimming, use Class 1
wiring methods only. If dimming is not being used ensure to
cap off the violet lead.
e. If 0/1-10V Dimming is used, connect the pink fixture lead to
the supply negative dimming lead. For dimming, use Class 1
wiring methods only. If dimming is not being used ensure to
cap off the pink lead.
Tuck all wires carefully into wiring chamber ensuring that no wires are
pinched.
LINE OR HOT 1
NEUTRAL OR HOT 2
888.243.9445
|
FAX: 262.504.5409
Date
ECR#
LUMINAIRE
LINE - BLACK
NEUTRAL -
WHITE
GROUND
BARE OR
GREEN
DIM (+)
VIOLET
DIM (-)
PINK