6.
Temperature loads
Operating / ambient conditions
Standard: 5 ... 55 °C; IP 54; 93 % rel. humidity
Sealed: 5 ... 55 °C; IP 65; 93 % rel. humidity
Media temperatures

Configuration

Heat - battery supplied
Heat - externally supplied
Cold - battery supplied
Cold - externally supplied
1) Only in riser / downpipe or in horizontal, tilted mounting
position
Note that in heat applications, the water tem-
perature must be greater than the ambient tem-
perature.
Once commissioned, avoid frost at the meter.
Use unsealed flow sensors:
at water temperatures permanently above ambient
temperatures
Use sealed flow sensors:
For cold applications or T
If permanent condensation is expected
7.
Disposal
The meter (standard version) contains a lithium
battery, which is not rechargeable. Do not use
force to open the battery.
It must never come into contact with water,
short-circuited or exposed to temperatures over 75 °C.
Empty batteries and no longer required electronic devic-
es or components are hazardous waste.
This device must not be disposed together with the do-
mestic waste.
Return it to the manufacturer for recycling.
8.
Declaration of conformity for MID meters
See from page 52 onwards.

Temperature range

5 ... 90 °C / 5 ... 105 °C
q
0:6 ... 2:5 m³/h:
p
5 ... 130 °C
q
3:5 ... 60 m³/h:
p
5 ... 150 °C
5 ... 90 °C / 5 ... 105 °C
5 ... 120 °C
< T
water
ambient
1)
1)
9