5. WIRING
5.2 INDEPENDENCE POWER SUPPLY (For QUS030~060)
Wiring figure
Indoor
Unit
Ground wiring
Power supply and connecting wires specification
Model(Btu/h)
Phase
Frequency and volt
Indoor
Rated Current
Fuse Rating(Field Supply)
Power Cord(Field Supply)
Phase
Frequency and volt
Outdoor
Rated Current
Circuit Breaker(Field Supply)
Power Cord(Field Supply)
Indoor/outdoor connecting wiring
(Field Supply)
All manuals and user guides at all-guides.com
Power supply
Switch/Fuse
Power Cord
Outdoor
Unit
30k
2.0A
10A
H05VV-F;
3×1.0mm
2
1-Phase
220-240V~ 50Hz
19.0A
50A
H07RN-F;
3×2.5mm
2
Shielded wire;
2×0.2mm
2
Power supply
Switch/Fuse
Power Cord
Ground wiring
Signal line (Low voltage)
36k
48k
1-Phase
220-240V~ 50Hz
2.0A
10A
H05VV-F;
H05VV-F;
3×1.0mm
2
3×1.0mm
1-Phase
1-Phase
220-240V~ 50Hz
220-240V~ 50Hz
23.0A
50A
H07RN-F;
H07RN-F;
3×4.0mm
2
3×4.0mm
Shielded wire;
Shielded wire;
2×0.2mm
2
2×0.2mm
2.0A
10A
2
26.5A
70A
2
2
GB-18