ADDITIONAL INFORMATION

User Maintenance

NOTE THAT THIS EQUIPMENT SHOULD ONLY BE DISMANTLED BY PROPERLY TRAINED PERSONNEL.
REMOVING THE FRONT OR REAR PANELS EXPOSES POTENTIALLY LETHAL MAINS VOLTAGES. THERE ARE
NO OPERATOR MAINTAINABLE PARTS WITHIN THE EQUIPMENT.
In the unlikely event that you experience any problems with your unit which cannot easily be remedied,
you should contact your supplier and return the unit if necessary. Please include any details of the fault
observed and remember to return the unit in its original packing. Cole-Parmer will accept no responsibility
for any damage to units that are improperly packed for shipment. If in doubt, contact your supplier. See
the Decontamination Certificate supplied with your unit.

Cleaning

Before cleaning your unit, ALWAYS disconnect it from the power supply and allow it to cool below 50°
C. Your unit can be cleaned with a cloth dipped in water or ethanol (methanol can also be used). No part
of the case or cover should be immersed in the solvents. Do not use acetone or abrasive cleaners.
Before using any cleaning or decontamination method except those recommended in this manual, the
responsible body should check with Cole-Parmer that the proposed method will not damage the
equipment.

Fuses

Your unit is protected by two fuses. They should only be changed by suitably qualified
personnel. If the fuses blow persistently, a serious fault is indicated and you may need to return the unit
to your supplier for repair.

Fault Finding

HELP display: If HELP is displayed there is a problem with the internal sensing device. The calibrator
should be returned to your supplier for repair.
Over-temperature cut-out: If the over-temperature cut-out trips it can be reset by switching the unit
off, waiting a few seconds,then swiftly it on again. If it repeatedly trips, please contact your local supplier.
Should you have any problems with your Calibrator which cannot be easily remedied, you should contact
your supplier and return the unit if necessary. Please include details of the fault observed and remember
to return the unit in its original packing. Antylia Scientific Ltd. accepts no responsibility for damage to
units which are not properly packed for shipping: if in doubt, contact your supplier, giving the full serial
number of the unit.

TECHNICAL SUPPORT AND SERVICING

If you require further technical or application assistance please contact:
Email: cptechsupport@antylia.com
Phone: +44 (0)1785 810433
For servicing information please contact:
Antylia Scientific Ltd. Service Department, Beacon Road, Stone, Staffordshire, ST15 0SA,
Email: cpservice@antylia.com.
Phone: +44 (0)1785 810475
We are continually striving to improve our products and software. If you have any comments and
suggestions on how we can do things better please send them to us at: cptechsupport@antylia.com