GENERAL FUNCTIONAL DESCRIPTION
This lock is used with a 6-digit number code and
can be programmed with a second code.
Each button pressing (except for ENTER) is
validated by a short buzzer signal and the green
LED. If the buttons are not pressed for 10 seconds
or the full time of code entry exceeds 30 seconds,
the lock is turned off.
If the code is incorrect, there will be a long buzzer
signal and the red LED will come on. If an incorrect
code is entered three times, the keypad will block
for 5 minutes, and within this period of time the
red LED will be flashing every 5 seconds (in this
case, the lock cannot be opened even if you enter
the correct code). Entering more than 8 digits is
considered as an incorrect code entry, if a 9th
button is pressed this will be indicated by a long
buzzer signal and the red LED, after which you
have to re-enter the code.
If you enter less than 6 figures (except for
pressing "*" and "ENTER" buttons) with pressing
the "ENTER" button, it is not considered as an
incorrect code entry.
1. HOW TO OPEN THE LOCK
1.1. Press button "ON" – the buzzer signals once
and the green LED light comes on;
1.2. Enter the primary code or the user code (from
6 to 8 figures). The default primary code is
1-2-3-4-5-6, user code is not activated);
1.3. Press button "ENTER" and turn the handle to
open the safe.
2. HOW TO CLOSE THE LOCK
The lock is closed automatically in 5 seconds
after the code entry and pressing "ENTER".
2.1. Turn the handle to position "closed" to lock
the safe.
3. PROGRAMMING
3.1. Programming the Primary Code
- Press button "ON";
- Press button "ENTER";
- Press button "1";
- Press button "ENTER";
- Enter the valid primary code and press "ENTER";
- Enter the new primary code (from 6 to 8 figures)
and press "ENTER";
- Re-enter the new primary code and press
"ENTER".
Acoustic and light signals are the same as for the
lock opening. The correct entry of valid or new
primary code is indicated by two buzzer and green
light signals. An incorrect entry of valid or new
primary code (less than 6 figures or an incorrect
re-entry) is indicated by a long buzzer signal and
the red light. A mistake in the procedure sequence
is indicated a long buzzer signal and the red light.
In these cases you have to restart the procedure
by pressing "ENTER".
3.2. Programming the User Code (with the
Primary Code)
- Press button "ON";
- Press button "ENTER";
- Press button "2";
- Press button "ENTER";
- Enter the valid primary code and press "ENTER";
- Enter the user code (from 6 to 8 figures) and
press "ENTER";
- Re-enter the user code and press "ENTER".
Acoustic and light signals are the same as for the
primary code programming.
3.3. Programming the User Code (without
the Primary Code)
- Press button "ON";
- Press button "ENTER";
- Press button "3";
- Press button "ENTER";
- Enter the valid user code and press "ENTER";
- Enter the new user code (from 6 to 8 figures)
and press "ENTER";
- Re-enter the new user code and press "ENTER".
Acoustic and light signals are the same as for the
primary code programming.
3.4. User Code Deletion
- Press button "ON";
- Press button "ENTER";
- Press button "0";
- Press button "ENTER";
- Enter the valid primary code and press "ENTER";
The user code is deleted, only the primary code
is valid.
Acoustic and light signals are the same as for the
user code programming.
4. POWER SUPPLY CONTROL
If the voltage of the power supply is decreasing,
the buzzer and the red LED signal five times after
pressing button "ON".
4.1. To replace the battery:
- If the door is closed, you need to connect the
battery to the supply clip ("+" and "-" respectively)
between the handle and the keypad. Then enter
the valid code, turn the handle clockwise and
open the safe door.
Current-conducting contacts
Attention!
If you connect the battery from external side, it
is necessary to observe the polarity and provide
a close connection of the battery to the clip on
the keypad.
Requirements to the Battery
Model - 6LR61
Voltage - 9V
Battery Type - ALKALINE
4.2. Replacing the Discharged Battery
In order to change the main battery, it is
necessary to twist off the screw on the back
side and take the cover off. Then take the plastic
cap off, take out the discharged battery and
disconnect it. After that, connect the new battery
(pay attention to the polarity).
Finally, close the plastic cap of the lock and the
cover on the back side of the door.
Attention!
Having changed the battery, it is strongly
recommended to check the new battery by
opening and closing the lock two or three times
while the door is opened. Only after that, you
shoudl close and lock the door.
5. SERVICE
5.1. Troubleshooting
At the start-up the device is self-tested. After
that the device is turned off.
If one of the codes was changed but the saving
failed, the buzzer with both LEDs signal it three
times. After that the operation of the device
continues with the codes which were valid before
they had been changed.
5.2. Primary Code Change Failure Diagnostics
This function is a service function and is
necessary for identifying the valid primary code.
- Press button "ON";
- Press button "ENTER";
- Press button "4";
- Press button "ENTER";
- Enter service code "160400" and press button
"ENTER";
If the lock was opened by the valid primary code
at least once, then after pressing "ENTER" the
buzzer and the green LED will signal for 5 times.
If the lock has never been opened by the valid
primary code, then after pressing "ENTER" the
buzzer and the red LED will signal for 5 times.
PROGRAMMING OF OPEN DELAY / OPENING
FRAME FUNCTIONS
Time delay function – a time period after which
it is possible to open the lock.
Opening frame – a time period after the time
delay period during which it is possible to open
the lock by entering a valid password combination.
Attention!!! All programming procedures must
be conducted after opening the safe door.
Conventional Symbols