INSTRUCTION FOR SERVICING(R32)

24. Check the information in this manual to find out the dimensions of space needed for
proper installation of the device, including the minimum distances allowed compared to
adjacent structures.
25. Appliance shall be installed, operated and stored in a room with a floor area larger than 4m
26. The installation of pipe-work shall be kept to a minimum.
27. The pipe-work shall be protected from physical damage, and shall not be installed in
an unventilated space if the space is smaller than 4m
28. The compliance with national gas regulations shall be observed.
29. The mechanical connections shall be accessible for maintenance purposes.
30. Follow the instructions given in this manual for handling, installing, cleaning, maintaining
and disposing of the refrigerant.
31. Make sure ventilation openings clear of obstruction.
32. Notice: The servicing shall be performed only as recommended by the manufacturer.
33. Warning: The appliance shall be stored in a well-ventilated area where the room size corresponds
to the room area as specified for operation.
34. Warning: The appliance shall be stored in a room without continuously operating open flames
(for example an operating gas appliance) and ignition sources (for example an operating
electric heater).
35. The appliance shall be stored so as to prevent mechanical damage from occurring.
36. It is appropriate that anyone who is called upon to work on a refrigerant circuit should hold a
valid and up-to-date certificate from an assessment authority accredited by the industry and
recognizing their competence to handle refrigerants, in accordance with the assessment
specification recognized in the industrial sector concerned. Service operations should only be
carried out in accordance with the recommendations of the equipment manufacturer.
Maintenance and repair operations that require the assistance of other qualified persons must
be conducted under the supervision of the person competent for the use of flammable
refrigerants.
37. Every working procedure that affects safety means shall only be carried out by competent persons.
38. Warning:
a.
clean, other than those recommended by the manufacturer.
b.
operating ignition sources (for example: open flames, an operating gas
appliance or an operating electric heater.
c.
Do not pierce or burn.
d.
Be aware that refrigerants may not contain an odor.
Caution: Risk of fire
Do not use means to accelerate the defrosting process or to
The appliance shall be stored in a room without continuously
Operating instructions