TEST AND ADJUSTMENT
❒ Turn on the circuit breaker and light switch.
NOTE: Sensor has a 1
before it will detect motion. When first turned
on, wait 1
NOTE: Meets the ENERGY STAR
D
B
function is off and ON-TIME is 1 or 5 minutes
®
ual
rite
and when used with 120 W Max bulbs.
❒ Turn the RANGE control to the medium position
(halfway between MIN and MAX), D
and the ON-TIME control to the TEST position.
MAX
MIN
RANGE
Avoid aiming the sensor at:
• Objects that change temperature rapidly, such as
heating vents and air conditioners. These heat
sources could cause false triggering.
• Areas where pets or traffic may trigger the control.
• Nearby large, light-colored objects reflecting light
may trigger the shut-off feature. Do not point other
lights at the sensor.
15 ft.
(4.6 m)
DualZone™
Maximum Range
Get user manuals:
See SafeManuals.com
/
minute warm up period
1
2
/
minutes.
1
2
guidelines when
®
B
ual
rite
ON-TIME
DUAL BRITE™
TEST 1 5 20
OFF 3 6 DUSK TO
MINUTES
HOUR
DAWN
Bottom of Sensor
DualZone™
70 ft.
100 ft.
(21 m) (30.5 m)
Boosted
Maximum
Coverage Angle
NOTE: If fixture is mounted higher than 8 ft. (2.4 m), aiming
the sensor down will reduce coverage distance.
The detector is less sensitive to motion directly towards it.
Motion
DualZone™
Least Sensitive
to OFF,
®
❒ Loosen the clamp screw in the
sensor ball joint and gently
rotate the sensor.
❒ Walk through the coverage
area noting where you are
when the lights turn on (also,
the LED will flash several times
when motion is detected). Move
the sensor head up, down, or
sideways to change the cover-
age area. Keep the sensor at
least 1" (25 mm) away from
the bulbs.
❒ Adjust the RANGE as needed.
RANGE set too high may
increase false triggering.
❒ Secure the sensor head by
tightening the clamp screw.
Do not overtighten the screw.
❒ Set the amount of TIME you want the lights to stay
on after motion is detected (1, 5, or 20 minutes).
240°
❒ Set the D
ual
dusk you want the lights on at low level (Off, 3, 6
Hrs., Dusk-to-Dawn).
WARNING - Risk of fire. Do not aim the bulbs
at a combustible surface within 3 ft. (1 m).
NOTE: DualZone™ is a new zone of detection which
was added as an option to select Heath
sensing products. This feature adds a zone of detec-
tion under the motion sensor. DualZone™ requires
no additional adjustment and operates in conjuction
with the forward-looking sensor.
4
Motion
DualZone™
Sensor
Most Sensitive
Aim Sensor
Down for Short
Coverage
Aim Sensor
Higher for Long
Coverage
B
switch to the amount of time after
®
rite
/Zenith motion
®
Clamp
Screw
Ball
Joint
598-1152-03