241(PLC: 40242) t_DHWHP_max
242(PLC: 40243) t_DHWHP_restrict
243(PLC: 40244) T4autocmin
244(PLC: 40245) T4autohmax
245(PLC: 40246) T1S_H.A_H
246(PLC: 40247) T5S_H.A_DHW
247(PLC: 40248) PER_START ratio
248(PLC: 40249) TIME_ADJUST
249(PLC: 40250) dTbt2
250(P LC: 40251) IBH1 power
251(PLC: 40252) IBH2 power
252(P LC: 40253) TBH power
253(PLC: 40254 Comfort parameter
254(P LC: 40255) Comfort parameter
255(PLC: 40256) t_DRYUP
256(PLC: 40257) t_HIGHPEAK
257(PLC: 40258) t_DRYD
258(PLC: 40259) T_DRYPEAK
259(PLC: 40260) t_firstFH
260(PLC: 40261) T1S (first floor heating)
Longest duration of water heating by the heat pump, range:
10~600 min, default setting: 90 min;
Duration of limited water heating by the heat pump, range: 10~600
min, default setting: 30 min;
Default setting: 25°C, range: 20~29°C, setting interval: 1°C
Default setting: 17°C, range: 10~17°C, setting interval: 1°C
Default setting: 25°C, range: 20~25°C, setting interval: 1°C
In the holiday mode, setting of T1 in the water heating mode,
range: 20~25°C, default setting: 25°C
Range10-100, default setting10.Setting interval10
Range1-60 default setting5
Rrange0-50 default setting15
Range0-200, default setting0, unit: 100W
Range0-200, default setting0, unit: 100W
Range0-200, default setting0,unit: 100W
Reserved, wrong address is reported whe n this register is queried
Reserved, wrong address is reported whe n this register is queried
Temperature rise day number, range: 4~15 days, default setting:
8 days
Drying day number, range: 3~7 days, default setting: 5 days
Temperature drop day number,
setting: 5 days
Highest drying temperature, range: 30~55°C, default setting: 45°
C
Running time of floor heating for the first time, default setting: 72
hrs, range: 48-96 hrs
T1S of floor heating for the first time, range: 25~35 ° C, default
setting: 25°C
57
range:
4~15 days, default