Descargar Imprimir esta página

Assigning A Zone To The External Wall Movement Detector (Protexial Io Only) - SOMFY 1875141 Manual

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

Assigning a zone to the external wall movement detector (PROTEXIAL io only)

The operating mode of the external wall movement detector can be selected:
Either using the 2 switches located inside the detector
Or locally on your computer, from the "Device list" page in the Installer menu.
The choice of zone on the computer overrides the positions of the switches on the device.
Using the switches inside the detector:
If you choose to set the operating mode using the switches,
you can define:
Either a setting for operation in alarm mode
Or a setting for operation in pre-alarm mode
Positions of the
Zone
switches
AD
(default)
A
AX
1
AX
2
(1) Activate this function in the LCD keypad menu (see menu 7641 in the installation manual or "Scenario settings" on your
computer).
(2) Set this delay in the LCD keypad menu (see menu 775 in the installation manual or "Advanced settings" on your computer).
From a computer (PROTEXIAL io only):
Copyright © 2018 Somfy Activités SA. All rights reserved.
What happens in the event of intrusion
(in partly or fully armed mode)
If zone A is armed:
■ Chime!
(if KIELA™
function on)
If zones A, B and C are armed:
Immediate triggering of the sirens, flash, dial-up, roller shutter lowering
and light control activation
If zone A is armed:
■ Chime!
(if KIELA™
function on)
If zone A is armed:
■ Chime!
(if KIELA™
function on)
AD
A
AX1
AX2
Switch
If zones A, B and C are armed:
Delayed triggering of the sirens, flash, dial-up and
roller shutter lowering
light control activation
Recording in the log (menu 6 "Event log")
If zones A, B and C are armed:
■ BEEP!
on the sirens
Triggering of the flash on the outdoor siren
If zones A, B and C are armed:
■ BEEP!
on the sirens
Triggering of the flash on the outdoor siren
Light control activation (if a receiver is present)
Delayed lowering of the roller shutters
after the entry delay and
(1)
(2)
(1)
53

Publicidad

loading

Este manual también es adecuado para:

1875108