Descargar Imprimir esta página

JL Audio XDM200/2 Manual Del Propietário página 3

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

CONNECTIONS
1
Connection
Description
+12 VDC
Positive (+12V) Power Connection
1
Ground
Negative (GND) Ground Connection
Remote
Positive (+12V) Activation Connection
CH. 1 Input
Left Input Signal, Black RCA
CH. 2 Input
Right Input Signal, Red RCA
2
Preout 1
Left Pass-Through Preamp Signal, Black RCA
Preout 2
Right Pass-Through Preamp Signal, Red RCA
Remote Level
Remote Level Controller Connection (optional)
3
Control
(HD-RLC or MHD-RLC)
(+) Positive Speaker Output
CH. 1 (L)
Speaker
Output
(–) Negative Speaker Output
4
(+) Positive Speaker Output
CH. 2 (R)
Speaker
Output
(–) Negative Speaker Output
4 | JL Audio® - XDM200/2
2
3
4
Notes
• 4 AWG wire (8 AWG minimum)
• Install 20A fuse at (+) battery post
• 4 AWG wire (required)
• 18 – 12 AWG wire capacity
• See
Turn On Mode for more info
• Accepts 200mV – 4V input voltage
• See
Input Mode for more info
• Same signal that is connected to
CH. 1&2 inputs
• Unaffected by the amplifier's filters
• Operates as an attenuator only:
Fully counter-clockwise = Level Muted
Fully clockwise = Level Unaffected
• Multiple amplifiers can be controlled
from a single HD-RLC using a non-
duplex phone line splitter and multiple
phone cables.
CH. 1&2 Bridged (+)
• Minimum impedance load:
Stereo mode ≥2 ohms
Bridged mode ≥4 ohms
• 16 – 8 AWG wire capacity
CH. 1&2 Bridged (–)
CONTROLS
Control (Function)
Setting
Flashing
Amplifier Powering Up, Audio Output Muted
Green
Green
On-Normal Operation, Active Audio Output
On-Safe Mode, Over-Temperature Condition, Audio Output Reduced
Red
Status LED
• Reverts to normal operation when temperature returns to a safe level
5
( indicates operating
On-Safe Mode, Over-Current Condition, Audio Output Muted
status)
Amber
• May exhibit repetitive, audible ticking or thumping noise in the output
(yellow)
• Inspect for speaker/wire short circuit or low impedance
Amplifier Turns Off (unexpectedly), Low-Voltage Condition
LEDs Off
• Occurs when battery or remote turn-on voltage drops below 10V
• Reverts to normal operation when voltage rises above 11V
+12V Remote Turn-On (Preferred)
Remote
• Controlled by a switched +12V circuit or turn-on out-
put of your source unit/OEM interface
DC Offset-Sensing (Automatic)
Turn On Mode
• Turns On by detecting the presence of small DC
Offset
signal in OEM audio outputs and turns Off after
( configures
the signal is removed
activation method)
6
Signal-Sensing (Automatic)
• Turns On by detecting full-range OEM audio
Signal
signals and turns OFF after the signal is removed
(within 30 seconds)
Input Filter
Car
Select for most installations (automotive or marine)
( configures input
filter application)
Boat
Select if experiencing interference from high-current mechanical switches/devices
Input Sens.
( adjusts each
Use to match the source unit's output voltage with the inputs of each pair of amplifier
Variable
channel pair's input
channels. See Appendix A for detailed information.
stage)
Filter Mode
Off
Filter defeated; passes full range of frequencies present at the inputs
( configures
7
the filter of CH.
HP
Attentuates frequencies below the CH. 1&2 "Filter Freq. (Hz)" dial, at a rate of 12dB/octave
1&2)
LP
Attentuates frequencies above the CH. 1&2 "Filter Freq. (Hz)" dial, at a rate of 12dB/octave
Filter Freq. (Hz)
( adjusts filter
Use to adjust the cutoff frequency of channel 1&2's active filter,
cutoff frequency)
Variable
from 50 Hz – 500 Hz / 12dB per octave
5
6
Description
• Designed for high-level
(speaker) signals only
• Detects input signal from
CH. 1 (L) only
• Using DC Offset or Signal
Sensing methods will turn the
"Remote" terminal into a +12V
turn-on output.
5

Publicidad

loading