ALARM MESSAGES :
NO ACC
Is displayed in the event of an ignition error.
In this case, the stove goes into controlled
cooling. Erase the message by pressing
more than 2 seconds.
NO FIRE
Is displayed in the event of unwanted
extinction of the stove. In this case, the stove
goes into controlled cooling.
Erase the message by pressing
than 2 seconds.
SERV
Is displayed when the stove has reached 1,200
hours of operation.
In this case, please contact the approved
service center for seasonal maintenance.
CLEANING
Before carrying out any maintenance on the stove, take the following precautions:
• Ensure that all parts of the stove are cold;
• Ensure that the ashes are completely extinguished;
Daily cleaning
1
Turn the stove off by
The scraper makes it possible to take off the soot
placing the switch on
accumulated on the thermal exchange pipes.
"0"
• Take out the scraper using the key supplied
• Operate the scraper several times.
6
Take out the ashtray.
10
Vacuum all the ashes in the brazier, the ashtray,
and the flame protection. Make sure that all
holes in the brazier let the air pass.
BLACK OUT
Is displayed if the power supply was cut
during the operation of the stove. In this case,
the stove goes into controlled cooling. Erase
the message by pressing
for
seconds.
DEP SIC FAIL
Is displayed in the event of an anomaly
detected by the pressure probe or the
thermostat. In this case, the stove goes into
controlled cooling.
Erase the message by pressing
for more
than 2 seconds.
Have the thermostat safety devices checked
by an approved service center.
2
7
Lift the flame protection to
release it.
for more than 2
for more
• Make sure the main switch is in position "0";
• Disconnect the plug, thus avoiding any accidental contact;
3
8
Pivot the flame protection.
11
Vaccum the brazier support and all
the accessible parts
53
FAN FAIL
Is displayed in the event of a smoke extraction
fan failure. In this case, the stove goes into
controlled cooling.
Erase the message by pressing
than 2 seconds.
HOT PCB
Is displayed if, during operation, the electronic
card reaches and exceeds 70 ° C for more
than 3 minutes. In this case, the stove goes
into controlled cooling. Erase the message by
pressing
for more than 2 seconds.
Have the stove checked by an approved
service center.
4
5
Open the door
Take the brazier out of the
and suck up the
stove.
accumulated ashes.
9
Remove the flame protection.
EN