Descargar Imprimir esta página

Westinghouse WGen12000c Manual Del Usuario página 15

Publicidad

Idiomas disponibles

Idiomas disponibles

using the generator may require grounding to reduce the
risk of shock or electrocution.
Before using the ground terminal, consult a qualified
electrician, electrical inspector, or local agency having
jurisdiction for local codes or ordinances that apply to the
intended use of the generator.
DISCONNECTING THE BONDED NEUTRAL
Removing the bonded neutral disables the GFCI protection
from the 5-20R receptacles. The bonded neutral should
only be removed under specific circumstances. Consult a
qualified electrician to determine if your situation requires
disconnecting the bonded neutral.
1. Remove the alternator cover.
2. Remove the bonded jumper wire and reinstall the nut.
3. Remove the nut securing the neutral ground wire and
attach the bonded jumper wire. Reinstall the nut.
4. Reinstall the alternator cover.
IMPORTANT: Apply a new "NEUTRAL UNBONDED"
Label over the "NEUTRAL BONDED TO
FRAME" label on the front of the control
panel.
Westinghouse Outdoor Power Equipment | 15

Publicidad

Solución de problemas

loading