AC Power
This product has an auto-ranging power supply that works with an input voltage range of 100 to 240 VAC, 50/60 Hz.
To eliminate wear and improve its lifespan, during periods of non-use completely disconnect the
product from power via breaker or by unplugging it.
Power Linking
It is possible to power link up to 19 COLORband PiX ILS products on 120 VAC or up to 35 COLORband PiX ILS products
on 230 VAC.
Fuse Replacement
1. Disconnect the product from power.
2. Using a Phillips-head screwdriver, unscrew the fuse holder and pull it straight out.
3. Remove the blown fuse from the holder and replace with a fuse of the exact same type and rating.
4. Re-insert the fuse holder and reconnect power.
Mounting
Before mounting this product, read the
Mounting Diagram
Mounting clamp
(such as CLP-15N from Chauvet)
Mounting bracket
Control Panel Description
Button
Function
<MENU>
Exits from the current menu or function
<UP>
Navigates upwards through the menu list and increases the numeric value when in a function
<DOWN>
Navigates downwards through the menu list and decreases the numeric value when in a function
<ENTER>
Enables the currently displayed menu or sets the currently selected value into the selected function
COLORband PiX ILS QRG Rev. 3
QUICK REFERENCE GUIDE
Safety
Notes.
Safety cable
(such as CH-05
from Chauvet)
Bracket adjustment knob
(x2)
EN
2