3.6 Residual risks

The existing residual risks include:
- Contact with the saw blade in the area of the start-up opening below the base plate.
- Contact with the part of the saw blade that protrudes below the workpiece during the cutting process.
- Contact with rotating parts from the side: Saw blade, clamping flange and flange bolt.
- Kickback of the machine when jammed in the workpiece.
- Breakage and ejection of the saw blade or parts of the saw blade.
- Accidental switch-on when the rechargeable battery is not removed.
- Impaired hearing when working without hearing protection for long periods of time.
- Emission of harmful wood dusts during longer operation without extraction.
4

Setup / adjustment

4.1 Charging the rechargeable battery

Rechargeable battery and charger are matched to each other. Use only the MAFELL chargers for charging.
First, charge the rechargeable battery when you use a new machine.
The charging process is described in the "Charger APS M" instructions supplied.
A significantly shortened operating time after charging indicates that the rechargeable battery is exhausted and
needs to be replaced.
The rechargeable battery is equipped with a temperature monitor. This ensures that the rechargeable battery is
only charged in the optimal temperature range between 0 °C (32 °F) and 50 °C (122 °F). This ensures a long
battery life.
01/2022
Warning
Risk of injury when working with the machine
Even when the machine is used as intended and in compliance with the safety
regulations, there are still residual risks caused by the intended use, which can
have consequences for your health.
Observe the safety instructions and information in these instructions.