Pull out the plug of the seat contact
switch and push it back through the
opening.
Unlock the driver seat and pull it up-
ward.
Dismount the plug of the seat contact
switch from the holder.
Unhook the support of the seat console
and close the seat console.
Unscrew the hinges of the seat console.
Place the seat console in the foot
space.
Only with Dose variant: Disassemble
the trough for the detergent canister.
Only with Fleet variant: Remove the cable.
Lift battery cover.
Dismantle fresh water tank on the right
hand side.
Dismantle the side plate of the battery
box on the right hand side.
Insert battery. Battery connections in
front direction.
ATTENTION
Pay attention to correct poles.
Connect the connection cable to the
free battery poles (+) and (-). Lay the
cables in such a way that they do not
get clamped by the seat.
Only with Fleet variant: Reassemble the
cable.
Install the side plate of the battery box
on the right hand side.
Install fresh water tank on the right hand
side.
Replace battery cover.
Insert battery plug.
Position the seat console.
Tighten down the hinges of the seat
console.
Open the seat console and secure the
support for the seat console.
Mount the plug of the seat contact
switch to the holder.
Insert the seat.
Reconnect the plug of the seat contact
switch.
Install screw of seat stopper.
Swivel the seat downward.
Adjust steering wheel.
ATTENTION
Charge the batteries before commissioning
the appliance.
Charge the batteries
Note:
The appliance is equipped with a total dis-
charge protection, i.e. if the still admissible
minimum of the capacity is reached, the appli-
ance can only be driven. The display shows
the message "Battery low - cleaning not pos-
sible" and "Battery empty - please charge".
Drive the machine directly to the charg-
ing station; avoid any steep gradients in
the process.
Note:
When using other batteries (e.g. batteries
from other manufacturers), the total dis-
charge protection level for the respective
battery must be reset by the Kärcher after-
sales service.
DANGER
Danger of injury due to electric shock. Ob-
serve supply network and fuse protection -
see "Charger".
20
Only use the charger in dry rooms with suf-
ficient ventilation!
Note:
Average charging time is approx. 10 -12
hours.
The recommended chargers (suitable for
the batteries used) are regulated electroni-
cally and will automatically terminate the
charging process.
DANGER
Danger of explosion. The room, where the
machine is kept to charge the battery, must
feature a minimum volume and an air ex-
change with a minimum flow rate, depend-
ing on the type of battery (see "Recom-
mended Batteries").
Danger of explosion. Wet batteries may
only be charged with the seat tilted up.
Tilt the seat upward.
Remove battery plug and join it to the
charging cable.
Connect the charger to the mains and
turn it on.
After charging
Switch off the charger and remove the
plug from the socket.
Pull the battery cable from the charger
cable and connect it to the machine.
Low maintenance batteries (wet
batteries)
Add distilled water one hour before the
charging process comes to an end; fol-
low the correct acid level. There are
corresponding indicators on the battery.
At the end of the charging process, all
cells must gas.
WARNING
Danger of causticization!
– Adding water to the battery in its dis-
charged state can cause the acid to leak.
– Use safety glasses while handling bat-
tery acid and follow the safety instruc-
tions to avoid personal injury or damage
to clothes.
– Should the acid spray on to the skin or
clothes, rinse immediately with lots of
water.
ATTENTION
Risk of damage!
– Use only distilled or desalinated water
(EN 50272-T3) for filling the battery.
– Do not add any substances (so-called
performance improving agents), else
warranty claims will not be entertained.
Recommended batteries, chargers
Order No.
Battery set
6.654-136.0
Charger
6.654-295.0
Volume [m
} *
71,78
3
Air flow [m
/h] **
28,71
3
* Minimum volume of the battery charging
room
** Minimum air flow between the battery
charging room and the surroundings
Batteries and chargers are available in spe-
cialised stores.
4
-
EN
Maximum battery dimensions
Length
Width
842 mm
627 mm
If you use wet batteries in the BAT model,
then follow the following instructions:
– It is necessary to conform to the maxi-
mum battery dimensions.
– While charging wet (maintenance-free)
batteries, it is necessary to tilt the seat
upward.
– While charging wet batteries, follow the
specifications of the battery manufac-
turer.
Battery display
The charge condition of the batteries is
shown on the display of the control panel.
– The length of the bar indicates the
charge condition of the battery.
– During the last 30 minutes the remain-
ing operating time is indicated in min-
utes.
Unloading
Note:
To take all functions out of operation imme-
diately, bring the safety switch into the "0"
position.
Four floor boards of the pallet are fas-
tened with screws. Unscrew these
boards.
Place the boards on the edge of the pal-
let. Place the boards in such a way that
they lie in front of the four wheels of the
machine. Fasten the boards with
screws.
Slide the four support beams included
in the packaging under the ramp.
Only BR 120/250...: Remove front
transport eyelets from the palette.
Remove the wooden bars in front of the
wheels.
With battery
Sit on the driver seat.
Plug in the Intelligent Key.
Bring the safety switch into the "1" posi-
tion.
Set programme selector switch to trans-
port run.
Set the travel direction switch to "for-
ward".
Actuate the accelerator pedal.
Drive the appliance off the pallet.
Bring the safety switch into the "0" position.
Without battery
Release the park brake (see "Pushing
the appliance").
Height
537 mm