Initial startup
Dry vacuum cleaning
Install the non-woven filter bag and filter bag
1. Release and remove the suction head.
2. Install the non-woven filter bag and ensure correct
seating.
Illustration F
3. Fully unfold the filter bag.
4. Press the filter bag with the plastic ring on the device
connection with your fingers until it clicks into place.
Illustration G
5. Fit and lock the suction head.
Illustration H
Wet vacuum cleaning
Install the foam filter
Note
Before vacuuming up wet dirt, you must first remove the
filter bag and then remove the non-woven filter bag.
1. Release and remove the suction head.
2. Install the foam filter and ensure correct seating.
Illustration I
3. Fit and lock the suction head.
Illustration H
Accessory application
1. Connect the suction hose.
Illustration J
2. Connect the suction hose to the suction pipes.
Illustration K
3. Install the nozzles.
Connect the crevice nozzle to the suction pipes.
This is used for cleaning joints, grooves between
doors and windows, tiny slits, etc.
Illustration L
Connect the floor nozzle to the suction pipes (for
dry and wet vacuum cleaning).
This is used for cleaning hard surfaces.
Illustration M
Connect the main floor nozzle to suction pipes
(for dry vacuum cleaning).
This is used for cleaning carpet, floors, etc.
Illustration N
● Carpets and carpeted floors
Select the following switch setting:
Illustration O
● Hard surfaces
Select the following switch setting:
Illustration P
Starting up the device
1. Plug the mains plug into the socket.
Illustration Q
2. Set the ON/OFF switch to the desired position.
Illustration R
Position "1 (ON)": The suction / blowing function
is activated.
Position "0 (OFF)": The device is switched off.
Operation
Dry vacuum cleaning
ATTENTION
Vacuuming cold ashes
Device damage
Only vacuum cold ash with an ash pre-separator.
ATTENTION
Defective or wet non-woven filter bag
Device damage
Before starting up, check the non-woven filter bag for
damage, and replace it if necessary. Only vacuum with
a dry non-woven filter.
Depending on the equipment variant, a non-woven filter
bag is included. Always use the filter bag in addition to
the non-woven filter bag when dry vacuuming.
Note
Replace the filter bag in good time, as filter bags that are
too full can be damaged. The fill degree of the filter bag
depends on the amount of dirt vacuumed. The filter bag
should be replaced more frequently when vacuuming
fine dust, sand, etc.
Note
Filter bag order no.: 2.863-014.0.
Wet vacuum cleaning
ATTENTION
Wet vacuuming with a filter bag
Device damage
Do not use a filter bag when vacuuming wet.
ATTENTION
Operation with full container
When the container is full, a float switch closes the suc-
tion opening and the device runs at a higher speed.
Switch off the device immediately and empty the con-
tainer.
Note
If the device falls over, the float can also close. To make
the device capable of vacuuming again, set up the de-
vice, switch it off, wait 5 seconds and then switch it on
again.
Depending on the quipment variant, a foam filter is in-
cluded.
Note
Ensure the firm seating of the foam filter.
The blowing function can be used to clean areas that
are difficult to reach or where vacuuming is not possible,
e.g. leaves in a gravel bed.
Insert the suction hose into the blower connection.
The blowing function is now activated.
Illustration S
Interrupting operation
1. Set the trigger to "0 (OFF)".
The device is switched off.
1. Set the trigger to "0 (OFF)".
The device is switched off.
2. Pull out the mains plug.
Illustration T
3. Remove the device head.
Illustration C
4. Empty the container.
Illustration U
English
Filter bag
Blowing function
Ending operation
11