Descargar Imprimir esta página

Technical Data; Specified Conditions Of Use - Gude GPS-K AIR CUT 40 AK Traducción Del Manual Original

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 51
ENGLISH

Technical Data

20
Plasma cutter
Art. No
U
Rated input voltage AC Current
1
U
No-load voltage
0
Idle state power
Efficiency of the Welding Power Source
I
/ U
Performance range (Welding current / Load voltage)
2
2
X
Switch-on time
The ratio of given duration time/the full-cycle time. *
I
Maximum rated input current
1max
I
Maximum effective input current
1eff
Degree of protection
IP21S
Insulation class
Class H
Delivery Volume
Material thickness max.
Weight
This device consists of the following recyclable materials:
Sheet steel, Ccopper, Aluminum, ABS, PE
* The ratio of given duration time/the full-cycle time. Switch-on time determined at 40°C using simulation
control elements and how to use the appliance
properly. Abide by all the safety measures stated in
the service manual. Act responsibly toward third
parties. The operator is responsible for accidents or
risks to third parties.
In case of any doubts about connection and operati-
on refer please to our customer center
Class A (IEC 60974-10):
If you intend to use the apparatus in residential
surroundings supplied by the low voltage mains
supply, an electromagnetic filter may be required
to suppress electrical disturbance to a level where
they will no longer be a nuisance to the user.
The apparatus may be used in industrial or other
areas where power is not supplied by municipal
LV mains.
Class A apparatus are not intended for use in
residential areas where power is supplied via
municipal LV mains, since unfavourable power
conditions may cause interference.
As a user, you must make sure, after consultation
with your energy provider, if necessary, that your
Read and understand the operating
instructions before using the
appliance. Familiarise with the
I
= 40 A / U
= 96 V
2
2
I
= 23 A / U
= 89,2 V
2
2
I
= 18 A / U2
87,2 V
2
=
point of connection on which the machine is to be
operated meets the requirements above.
The user is responsible for faults arising from the
cutting.

Specified Conditions of Use

The plasma cutter with constant voltage characte-
ristic may only be used to cut electrically conductive
metals using air.
Only use the flame-cutting torch supplied.
Ambient temperature -10 °C - +40 °C
Relative air humidity max. 50 % (40 °C), 90% (20 °C)
Altitude above sea level max. 1000 m
The ambient environment must be free from
abnormal amounts of dust, acids, corrosive gases or
substances.
Respecting technical data and safety precautions.
Do not use this product in any other way as stated
for normal use. Not observing general regulations
in force and instructions from this manual does not
make the manufacturer liable for damages.
Requirements for operating staff 
The operating staff must carefully read the Opera-
ting Instructions before using the appliance.
GPS-K AIR CUT 40 AK
20095
230 V
268 V
6,3 W
89,2 %
15 A/86 V - 40A/96V
20 %
60 %
100 %
29,9 A
13,4 A
IP 21S
H
min. 80 l / min 2,0 bar
10-12 mm
20 kg

Publicidad

loading

Este manual también es adecuado para:

20095