Descargar Imprimir esta página

Suntec Wellness KLIMATRONIC DryFix 20 MAX Manual Del Usuario página 12

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 14
Continuous drainage
-
Take the drainage hose out from the water tank.
-
Find the drainage opening on the back of the device.
-
Put the drainage hose into the opening, put the other end of
the hose into a collecting vessel and pour out the water.
-
Make sure that the hose is securely connected to prevent
leakage of water.
Note: To avoid mould and bacteria, please clean the water tank regularly. Please fill it with clean water
with a little detergent. The tank should be shaken and then emptied and rinsed with clean water. Avoid
using cleaning agents, steel balls, chemical dust removers, diesel oil, benzene, thinners or other
solvents.
MAINTENANCE INSTRUCTION (picture 3)
1. Please always unplug the unit before cleaning.
2. Please note that only the dust filter may be cleaned.
3. Remove the front cover and carefully remove the dust filter.
4. If the filter is only slightly dusty, you can quickly and easily clean it with a vacuum cleaner.
5. If you are using an activated carbon filter, carefully remove the dirt and then put the filter back
into the appliance together with the dust filter.
6. Once the filter is cleaned, use the reset button to reset the filter change indicator.
7. Rinse the filter under running water (max. 40 ° C) and dry it with a soft cloth.
8. Clean the appliance with a damp cloth and then wipe with a dry cloth.
9. Do not use chemical solvents (such as benzene, alcohol) or hot water.
10. If the unit will not be used over longer period, please turn the power off, unplug the power cord
and take the unit in a dry, cool and safe place.
TROUBLESHOOTING
Problem
Hot air comes from the air outlet
The unit does not work.
The device does not
dehumidify.
The air does not flow out.
Cause
-----------
Is the unit plugged in?
Check the ambient
temperature.
Does the "tank full" indicator
(water tank is full or misplaced)
light up?
The unit is in defrost mode.
Is the air inlet or outlet blocked?
Is the ambient temperature or
relative humidity too low?
Is the air filter dirty?
Is the air inlet or outlet blocked?
Solution
The dehumidifier has no cooling
function; the air comes out of
the condenser. This is not a
defect.
Plug in the unit.
The temperature should be
between 5 - 35°C.
Empty the water tank and set it
to the correct position again.
This is a normal process and
helps to protect internal parts.
Once the process is complete,
the unit returns to normal
operation.
Check the air inlet and outlet
and remove any obstructions.
Please check the settings on
the unit. If the set humidity is
below the ambient humidity and
/ or 20%, the unit stops
dehumidifying.
Clean the air filter as described
in the manual.
Check the air inlet and outlet
and remove any obstructing
objects if necessary.

Publicidad