Descargar Imprimir esta página

Technical Data; Power Requirements - Truper MAX-20E Manual De Instrucciones

Publicidad

Technical Data

Code
Description
Discs
Voltage
Speed
IP Grade
Thread size
Battery
Charger
WARNING
Avoid the risk of electric shock or severe injury. When the power cable gets damaged
it should only be replaced by the manufacturer or at a
The build quality of the electric insulation is altered if spills or liquid gets into the tool while in use.
Do not expose to rain, liquids and/or dampness.
Before gaining access to the terminals all power sources should be disconnected.
WARNING

Power Requirements

WARNING
Tools with double insulation and reinforced insulation are
equipped with a polarized plug (one prong is wider than the other). This plug will
only fit in the right way into a polarized outlet. If the plug cannot be introduced into
the outlet, reverse the plug. If it still doesn't fit, call a qualified electrician to install
for you a polarized outlet. Do not alter the plug in any way. Both insulation types
eliminate the need of both a grounded third power cord with three prongs or a
grounded power connection.
WARNING
When using an extension cable, verify the gauge is enough for
the power that your product needs. A lower gauge cable will cause voltage drop in the line, resulting in power loss and
overheating. The following table shows the right size to use depending on cable's length and the ampere capability shown in
the tool's nameplate. When in doubt use the next higher gauge.
Ampere
Capacity
from 0 A and up to 10 A
from 10 A and up to 13 A
from 13 A and up to 15 A
from 15 A and up to 20 A
WARNING
When operating power tools outdoors, use a
extension cable labeled "For Outdoors Use". These extensions are specially designed for
operating outdoors and reduce the risk of electric shock.
Ion-lithium 20 V
Input:
The construction class of the charger is: Reinforced insulation
Number of
Conductors
3 (one grounded)
* It is safe to use only if the extensions have a built-in artifact for over current protection.
AWG = American Wire Gauge. Reference: NMX-J-195-ANCE-2006
MAX-20E
102449
Cordless angle grinder
4
/
"
1
2
20 V
10 000 RPM
IP20
5/8-11-UCN-1A
4 Ah | Charging time: 80 min approximately
Voltage:
127 V
Frequency: 60 Hz
Current:
1.1 A
The charger power cord has cord fasteners type: Y
The construction class of the tool is: Class III
Extension gauge
from 6' to 49'
18 AWG( * )
16 AWG
14 AWG
8 AWG
grounded
Output:
21.5 V
3.5 A
Authorized Service Center.
|
higher than 49'
16 AWG
14 AWG
12 AWG
6 AWG
ENGLISH
3

Publicidad

loading

Este manual también es adecuado para:

102449