SiThe cooker is mainly for indoor use over 20 m².
•
Always ensure that adequate ventilation is provided.
•
Always maintain an adequate distance to combustible materials, i.e. 100 cm above and 100 cm to the
sides as a minimum.
The cooker must be placed on a firm and level floor.
•
Never place the cooker in an explosive atmosphere such as in areas where gasoline or other flammable
•
liquids or gases are stored.
Use propane or butane gas only.
•
•
The pressure regulator and hose assembly to be used must meet local code standards.
The installation must comply with local codes or, in the absence of local codes, with the standard for the
•
storage and handling of liquefied petroleum gases.
A dented, rusted or damaged cylinder can be dangerous and should be checked by your cylinder supplier.
•
Never use a cylinder with a damaged valve connection.
•
The gas connections of the cooker are leak tested at the factory prior to shipment. A complete gas
tightness check must be performed at the installation site due to possible mishandling during shipment or
application of excessive pressure to the cooker.
Make a soap solution of one part liquid detergent and one part water. The soap solution can be applied
•
with a spray bottle, brush or rag. Soap bubbles will appear in case of a leak.
Make sure the safety control valve is in the OFF position. Turn on the gas supply.
•
In the event of a leak, turn off the gas supply. Tighten leaking fittings, then turn on the gas supply and
•
recheck.
Never leak test while smoking.
•
18
LOCATION OF THE COOKER
GAS REQUIREMENTS
LEAK TEST