2
Intended use / guarantee
The electrically operated vane cell pumps are suitable for decanting and bottling of diesel, fuel oil
or similar fluids that meet the Hazard Class A3, flash point above 55 ° C.
Viscous media of Hazard Classes A1 and A2 can not be delivered.
The integrated bypass valve in the pump body is at the limit of the max. delivery pressure.
A flow meter can be easily retrofitted to the pump.
The installation must not be operated in potentially explosive areas.
Any other use as well as modification or alteration of the installation and pump is only permitted
after consultation with the manufacturer.
If used as intended and in accordance with the instructions, we are liable under the statutory
warranty. The invoice from your dealer with the date of purchase must be enclosed with warranty
claims.
3
Assembly and delivery
The structure, including the individual components for the systems EP 55- S andEP 55- AZ, is
pictured on page 3, and on 4 for system EP 140. When the voltage is ready and the system is
switched on, the vane cell pump will begin to run.
The scope of delivery is shown in the order confirmation.
4
Set up and operation
4.1 EP 55-S and AZ
Assemble suction hose, dispensing hose and filling gun as shown in figure (page 3).
−
Place vane cell pump on the container. Insert suction hose into the opening of the container.
−
Attach pump to the container by means of the threaded barrel adapter.
Check all connections for a firm fit and leaks before starting the system.
The system is now operational.
−
Insert 230V mains plug into the socket.
−
Press the pump's on-switch. The vane cell pump starts to operate. Press the lever until
−
production commences.
The use of an automatic nozzle is of advantage for proper venting during commissioning of the
−
pump system, if the hose connection is opened slightly at the pump during the intake process
(max. ½ revolution).
When the system is not in use turn off the electric vane cell pump.
−
Do not allow the pump to run for longer than 5 min against the closed nozzle. Be aware that the
−
pump can heat up.
Observe safety instructions.
12
/ Benzstr. 16-24 / 63165 Mühlheim a. Main / Tel:+49(0)6108-906-0 / Fax:+49(0)6108-906-120
GmbH & Co. KG
MATO
Operating manual
EP55 / EP140