Maintenance

• The hydro pneumatic equipment does not require
maintenance only if taking the following caution measures:
• When there is risk of freezing empty the pump
completely removing the drain cap (B). Remember to
purge the pump before starting it back.
• Check periodically the foot valve (not included) and
clean if necessary.
• When the hydro pneumatic equipment will be used long
periods of time, we recommend emptying the pump fully
and rinse with clean water.

Troubleshooting

Problem
Cause
The motor does not
• There is no power.
start .
• The impeller is stuck.
The motor turns but is
• The foot valve filter is clogged.
not pumping water.
• Excessive suction height.
• Air in the inlet.
Not enough pressure.
• Suction height is in the limit.
• Foot valve filter partially clogged.
The overload thermal
• The motor is overheated.
protector is in
• The impeller is stuck.
operation.
B
Solution
• Check connections and voltage values.
• Remove the fan cover and turn the shaft to release it.
• Clean the filter.
• Shorten the suction pipe length.
• Check the suction pipe is hermetic. Assure the foot-valve is
submerged at least 20". Purge again the pump (see page 8).
Check the suction height.
• Shorten the suction pipe length.
• Clean the foot valve and the full suction pipe if necessary.
• Check tension and ventilation.
• Remove the fan cover and rotate the motor shaft to free it.
9
ENGLISH

Publicidad