Installation
We recommend use of our
telescopic wall box TM 150-045 for
laying through the outside wall.
Note:
Note:
Note:
Note:
Note:
Our condensate collector RV 060-
150 must be placed in the proximity
of the extractor to prevent the
ingress of water, i.e. condensate or
rain water from an uncovered
exhaust air shaft, into the extractor.
This condensate collector must still
be accessible after installation.
12
As standard, the wall extractor
blows out exhaust air in the upward
direction.
The bottom duct cover is included
in the packaging of the extractor
body.
The top duct cover has been
adapted individually by your
kitchen studio to the height of your
ceiling. It consists of one of the
following air ducts
-
LK 320-010 for ceiling heights of
2.30 m - 2.59 m (7'7"-8'6")
-
LK 320-020 for ceiling heights of
2.59 m - 2.88 m (8'6"-9'5")
-
LK 320-030 for ceiling heights of
2.88 m - 3.17 m (9'5"-10'4").
The above dimensions refer to a
distance of 1.60 m (5'3") between
the bottom edge of the wall
extractor and the floor.
If required, a side outlet is available
for the air duct.
Instructions on how to remove the
wall extractor from the packaging
can be found on the box covering
the extractor body.
Remove the wall extractor from the
packaging in accordance with these
instructions.
Impor
Impor
tant:
tant:
Impor
Important:
Impor
tant:
tant:
The wall extractor must not be
removed from the packaging by its
end pieces or by the two rods.