Descargar Imprimir esta página

Preparing For Installation; Remote Control - Sulion NATI Manual De Instalación

Publicidad

Note: The important warnings and instructions indicated in this manual are not guaranteed to cover all possible conditions and
situations that may occur. It must be understood that common sense, precaution, and care are factors that cannot be included in
all products. These factors can and must only be provided by the user who maintains and enjoys this fan.
Device technical spectifications
General
Nominal voltage and frequency
Protection category
Ingress protection
Work temperature
Maximun ceiling slope on which it can be installed
Weight
Power consumption in standby mode (W)
Service value measurement standard
Fan
Speed
Power (W)
RPM
Airflow (m³/min)
Airflow (m³/h)
Max noise level (dB)
Service value SV ((m³ / min) / W)
Maximum air speed (m / sec)
12
CIF A28763647
220-240V~AC 50/60Hz
+34 916774540
Calle Verano, 51 - Polígono Industrial Las Monjas -28850 Torrejón de Ardoz - Madrid (ESPAÑA)

Preparing for installation

Note: The estimated installation time is 120 minutes. This
product can only be installed by a certified electrician Ca-
refully separate the fan's parts, avoiding the use of cutters
or blades that could scratch any part of it.
Remove the fan from the packaging carefully, avoiding the
use of knives which could scratch any part of it.
Remove all the components. Place the motor on a cloth or
Clase I
wet surface so as not to damage its surface finish. Carefully
IP44
handle the unit to make sure that its casing does not bend
or get scratched.
-5
40ºC
The fan must be mounted on the floor or a large enough
15º
table to prevent any component from falling off.
4,5Kg
Instructions for synchronizing the
<0,5
receiver and the remote control
EN 62879:2020
The control is already factory-linked with its receive.
Make sure all connections are correctly made.
6
Make sure that the remote control contains batteries.
Make sure that all switches (main and isolation) are on.
30
200
The control of this fan have two mode of synchronization,
202
Universal mode and Unit mode:
- Unit Mode:
12100
This type of synchronization allows you to control two or
42
more nearby fans independently, each with its remote con-
6,73
trol.
2,46m/s
Synchronization:
The control of this fan does not require synchronization
with the receiver, the control is already factory-linked with
its receiver
- Universal Mode:
This type of synchronization allows you to control one or
more nearby fans with the same remote control.
Synchronization:
1.-Connect the power (wall switch) of the fan or fans that
you want to control, and then just within the following
15 seconds, press the key
continuous seconds.
2.-A "beep" sound indicates that the connection has been
executed and the equipment can function normally.
3.-Now, transmitter and receiver of the fan / s will have
been synchronized. Turn off the fan / s current using the
switch or automatic and then turn it back on / s, this step
is the one that closes the synchronization process.
Note: It is not possible for a controller to forget a fan once
it has been linked, if you want a fan to leave
to obey a command, another one must be linked to
"overwrite it".
ATC: 916749481 - info@sulion.es / SAT : 916749483 - sat@sulion.es

Remote control

Turn off
the fan
Speeds
Timer
of the remote control for 10
Nature
wind
Summer
/ Winter
13
www.sulion.es

Publicidad

loading

Este manual también es adecuado para: