Descargar Imprimir esta página

Signal Linking; Connecting And Cabling - Iluminarc LOGIC Graze S Guía De Referencia Rápida

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

DC Power
This product is powered by the LΩGIC Drive 2X with a CAT6 connection of 52-56 VDC. Download the User Manual for
the LΩGIC Drive 2X from
Power Linking
It is possible to link up to 6 LΩGIC Graze S products from one output of the LΩGIC Drive 2X.

Signal Linking

The LΩGIC Graze S will receive a control signal (DMX, RDM, Art-Net™, or sACN) from the LΩGIC Drive 2X via a CAT6
connection.

Connecting and Cabling

The LΩGIC Graze S has an IN port and an OUT port which require a CAT6/A ethernet connection.
LΩGIC Drive 2X
Cable requirements: ≥23 AWG (≥0.5733 mm) solid copper wire shielded CAT6/A, terminated with RJ45 connectors.
Stranded conductors not supported
Total Max Cable Length (LΩGIC Drive 2X to first fixture): ≤100 m / 328 ft
Total Max Cable Length (LΩGIC Drive 2X to last fixture): ≤140 m / 460 ft
Total Max Cable Length (first fixture to last fixture): ≤40 m / 131 ft
Patch Cable Guide
LΩGIC Graze S products mounted end-to-end can be connected by a CAT6 patch cable as short as 4.656 in
(118.27 mm) from plug to plug, give or take a quarter inch (6.35 mm).
(Ethernet port depth)
Cable length tolerances between manufacturers vary. Always verify that cables are a suitable length
before installing.
LΩGIC Graze S QRG Rev. 5
QUICK REFERENCE GUIDE
www.iluminarc.com
for more details.
0.494 in
12.56 mm
OUT
IN
IN
2.203 in
55.96 mm
3.417 in
86.8 mm
4.406 in
111.92 mm
4.656 in
118.27 mm
LΩGIC Graze S
OUT
OUT
IN
Measure cables from
plug to plug, as shown