The open front cooler cannot be installed in areas where it obstructs the passage as hallways,
emergency exits...
2 . 3
S T AR T I N G - U P .
Connect the open front cooler to the mains taking into account the aforesaid preventive
measures.
ATTENTION:
proper operation of equipment.
ATTENTION: If the power cable shows any sign of damage or
imperfections this cable should be replaced.
The open front cooler is a ready-to-use compact unit.
The power cord connection is located at the back of the open front cooler.
The use of extension cables or alternatively multiple power outlets should be avoided if at all
possible. If it is absolutely necessary, then make sure that the cables being used don't fall below
the minimum cross-section of 2.4mm
Only connect the open front cooler to power outlets with an earthing contact on a separate circuit.
More than 2 units should never be connected to one electric circuit.
Low voltage disconnects or unit disconnections are not permitted because they may lead to
malfunctions. If these safety regulations are not observed, then any claim from the guarantee
and/or compensation for damages are excluded.
ATTENTION: Only authorized service personnel may change the preset temperature on the
controller.
2 . 4
P R O D U C T L O AD I N G .
Make sure that the products do not block the ventilation grid.
IMPORTANT! Lack of maintenance will cause open front cooler to break down.
3.1
PERIODICAL MAINTENANCE.
Any intervention on the equipment required by the user to disconnect the power outlet. No
protection (grid or carter) must be removed by unqualified personnel.
Care and maintenance of your open front cooler:
Clean the condenser front grill at least once a month with a brush or vacuum cleaner.
Condenser must be cleaned at least 4 times a year with a vacuum cleaner.
Clean the inside and outside of the display with water and a nonaggressive detergent.
The grounding is necessary and obligatory for
2
.
3
G E N E R A L M A I N T E N A N C E .