TRIGGER
LOCK
TRIGGER
If you are using a genuine BINKS tip, follow the
instructions below to install the guard and tip. If
you are using a different tip, follow the
installation instructions provided with the tip that
you are using.
INSTALLATION OF THE TIP
AND GUARD
1. Make sure that the tip and tip guard are rated
for use at 7500 PSI. (Genuine BINKS parts will
be gray in color.)
2. Use seal alignment tool on
BINKS tip handle to insert
seal and pressure gasket
into back of guard, turn to
align with tip shaft opening.
3. Insert tip into opening on
BINKS guard.
NOTE
Narrow end of tip handle should be in
forward position for spraying.
4. Thread the guard onto gun head until it stops.
Tighten slightly with wrench – DO NOT OVER
TIGHTEN.
77-3084-R2.2 (7/2016)
BINKS AIRLESS 75M SPRAY GUN
SAFETY
GUARD
3/8-18 NPS
THREAD
9 / 14
CONNECTION TO THE HOSE
Attach a properly grounded fluid hose to the fluid
hose connection fitting (3/8 – 18 NPS thread) on
the bottom of the handle of your spray gun. Use
two (2) wrenches – one on the gun and one on
the hose. Tighten securely.
LOCKED
GUN OPERATION
1. Make sure your tip is in the spray position.
2. Start your sprayer following the instructions
provided in the equipment owner's manual.
3. Pull trigger to achieve flow through gun.
4. Adjust the fluid pressure on the sprayer until
proper atomization is achieved. Always spray
at the lowest pressure necessary to get the
desired atomization.
TIP CLOGS
If you are using a Genuine BINKS
follow the instructions below to clear a clogged
tip. If you are using a different tip, follow the
instructions included in the equipment manual
provided with that tip.
1. Engage Trigger Lock. Rotate tip handle 180° to
the reverse position.
2. Unlock trigger. Point the gun into a bucket
holding the gun nose away from you. Trigger
the gun briefly to expel the clog.
3. Engage Trigger Lock. Rotate tip handle 180° to
the spray position.
4. Unlock trigger. Spray a test to be sure the clog
is completely expelled.