OPERATING AND MAINTENANCE MANUAL
DEWATERING ELECTRIC PUMP XKS-P/PW SERIES
(6) to immerse the pump in a well or fountain.
2. Connect the power cable (3) to the main plug.
3. Fix the level switch (4) vertically as shown in the figure on the right, with the cable side at the bottom.
As long as the level switch is positioned vertically with the cable on the button, the pump will operate
independently of the water level.
During this process, air escapes through the plastic connector of the pump and you will see air bubbles
appear under the water. This is not a defect in your pump, but serves to vent the pump and will remove
any remaining air inside the pump. It may take several seconds of snubbing when the pump is first
submerged.
Note:
The position of the outlet hole may be different depending on which models. The main power
cables must not have a smaller cross-section than the rubber sheathed cables with the designation
H05RN-F and the designation H07RN-F.

4. ELECTRICAL CONNECTIONS

The plug on the pump cable must match the socket. Never modify the plug in any way. Do not use
any adapter plugs. Unmodified plugs and matching plugs will reduce the risk of electric shock.
Avoid body contact with earthed surfaces.
Do not abuse cord. Never use cord for carrying, pulling or unplugging pump. Keep cord away from
heat, oil, sharp edges or moving parts. Damaged or entangled cords increase the risk of electric
shock.
When operating a pump outdoors, use an extension cord suitable for outdoor use. Use of a cord
suitable for outdoor use reduces the risk of electric shock.
The pump is equipped with a compatible plug. The power supply in your country must comply with
international regulations.
If the power cord is damaged, it must be replaced by the manufacturer, its service agent or similarly
qualified persons in order to avoid hazards.
WARNING: Unsuitable extension cords can be dangerous. If an extension cord is used, it must be
suitable for outdoor use and the connection must be kept dry and off the ground. It is recommended
www.proindecsa.com / proindecsa@proindecsa.com