The Caramatic ProTwo can also be operated with only one gas cylinder.
The non-return gas valve prevents gas from escaping from the free connection.
When operating with only one gas cylinder, the free connection must be connected to the
Caramatic ProTwo can be closed by means of the sealing nut
Place the arrow of the withdrawal direction on the rotary knob in the direction of the
connected cylinder.
The gaskets at the inlet connections (if provided) must be replaced when re-assembling!
Make sure that the gaskets sit properly in the mounting and that the screws are tightened.
The LPG cylinder(s) must be upright when gas is being withdrawn.
Gas is withdrawn only from the gaseous phase.
The gas cylinder(s) must be secured so that it cannot topple over.
Protect gas cylinder(s) against radiant heat or heat from heating appliances.
Observe the installation regulations in the respective countries.

TROUBLESHOOTING

Fault cause
Gas smell
Leaking LPG is extremely
flammable.
Can cause explosions.
No gas flow.
In case of continuous gas escaping via the pressure relief valve PRV via the breather the
pressure regulator must be replaced with a new pressure regulator.
In case of gas smells, leaks, gas escaping via the PRV or faults in the consumption
equipment, SHUT DOWN THE SYSTEM immediately. Contact a specialised company.

MAINTENANCE

Upon proper ASSEMBLY and OPERATION, the product is maintenance-free.

REPLACEMENT

If there is any sign of wear or if the product or parts thereof are damaged, it must be
replaced. When the product has been replaced, observe the steps ASSEMBLY, LEAK
TESTING, and START-UP. To ensure that the installation works faultlessly under normal
operating conditions, it is recommended to replace system parts subject to wear or ageing,
e.g. pressure regulators, hose assemblies, shut-off devices, as required:
• Recommendation: replacement times 10 years.
The gasket in the inlet connector (if provided) must be changed every time the cylinder has
been replaced or disassembled. It must also be replaced if it is damaged or the connection is
no longer tight.
22 / 145
Action
 Close the gas supply.
 Do not use any electric switches.
 Do not use a phone in the vehicle.
 Ventilate rooms well.
 Shut down the LPG system.
 Contact a specialised company.
Gas feed is closed.
 Open the gas cylinder valve or shut-off fittings.
Filter sieve in the input connection is dirty.
 Send the pressure regulator to the manufacturer to be
checked.