Descargar Imprimir esta página

Examine The Charger; Maintenance; Clean The Charger; Store The Machine - Rubbermaid 2173520 Manual Del Propietário

Publicidad

Idiomas disponibles

Idiomas disponibles

EN
1. Put the battery pack into the charger.
If the status LED blinks RED, remove the battery pack
from the charger for 1 minute.
2. Put the battery pack into the charger again.
If the status LED blinks GREEN, the battery pack is good.
If the status LED stays blinking RED, remove the battery
pack and disconnect the charger.
3. Wait for 1 minute and put the battery pack into the charger
again.
If the status LED blinks GREEN, the battery pack is good.
If the status LED stays blinking RED, the battery pack
is defective and it is necessary to replace the battery
pack.
6.2

EXAMINE THE CHARGER

If the battery pack does not charge correctly:
1.
Examine the current of the power outlet with different
machines. Make sure that the outlet works.
2.
Examine the charger contacts to ensure they are not
short-circuited.
3.
If the charger is not under usual room temperature,
move the charger and battery pack to a location where
the temperature is between 6° C to 40° C (42.8° F to
104°F) .
If you attempt to charge the battery pack in a warm or hot
environment, and the charger LED light is red, remove the
battery pack and let the battery cool for approximately 30
minutes.
7

MAINTENANCE

7.1

CLEAN THE CHARGER

Keep the air vent free of blockage, saw dust, and wood dust.
Do not spray, wash, or submerge in water.
• Clear the unwanted material out of the air vent with a
vacuum.
• Clean housing and the plastic components with a soft, dry
cloth.
Do not use strong solvents or detergents on the plastic
housing or components.
WARNING
NOTE
IMPORTANT
English
7.2

STORE THE MACHINE

• Remove the battery pack before you store the charger or
disconnect the charger.
8

TROUBLESHOOTING

PROBLEM
Charger doesn't
work. Charger
shows defective
mode. (LED
flashes Red)
Charger doesn't
work. Charger
shows evaluation
mode (LED
indicates Red
solid ON).
9

TECHNICAL DATA

Model
Voltage
Input
Output
Battery Pack
Model
Battery pack capacity
Cell number
Battery manufacturer rating = 60V maximum and 54V
nominal. Actual voltage varies with load.
4
POSSIBLE
SOLUTION
CAUSE
Try to remove and
reinsert the battery
pack in the charger.
Battery pack or
Try charging a
charger is defective
different battery
or there is a bad
pack.
connection between
the battery pack
Unplug the charger
and charger.
and wait until the
red LED goes out,
then reconnect the
plug to the power
supply.
Allow the battery
pack to reach
normal temperature.
Battery pack is
Charging will begin
either too hot, or
when the battery
too cold.
pack returns to
3°C-47°C
(37°F-117°F).
2173520 / 2173896
60 V
120V AC 50/60Hz, 2.5A Max
60V DC 3.0A
2173664
4.0 AH
216 WH
15

Publicidad

loading

Este manual también es adecuado para:

2173896