Instructions on charging the battery pack can be
found in the operating instructions of the Metabo
charger.
Battery packs have a capacity and signal display
(17) (depends on design variant):
- Press the button (18), the LEDs indicate the
charge level.
- The battery pack is almost empty and must be
recharged if one LED is flashing.
6.2
Removing and inserting the battery pack
1. Press locking mechanism (15) and fold open the
protective cover (16) .
2. Slide on the battery pack (14) or remove it.
3. Close the protective cover (16) .
To prevent accidental starting, always insert
the battery pack only after assembly.
The device runs only when the protective cover is
closed.
The ideal storage temperature for battery packs is
between 10°C and 30°C.
Do not reach in the battery pack recess when
inserting the battery pack.
6.3
Storing the battery box (7) during pump
operation
The battery box can be permanently mounted on
the wall for storage near the container, suspended
with the fastening hook (e.g. rain barrel) or
positioned without a hook whilst observing all
specifications.
In any case, do not immerse the battery pack
unit in water and close the battery pack before
each use. Always position the battery pack box in a
dry and safe place!
a) Mounting the fastening hook* (25)
The mounting hooks (26) of the fastening hook (25)
are inserted into the recesses (23) on the underside
of the battery pack box (24) (step 1.) and the hook
(25) is pulled upwards (step 2.) so that it firmly fits in
the recesses. (see fig.D p. 3)
b) Wall fixture battery pack box (7)
On the rear side of the battery pack box there are
two mounting holes with spacing dimensions.
Ensure that the battery box is firmly screwed to the
wall using two suitable screws or hooks and hang it
securely from there.
6.4
Mounting multi-adapter (27)
Screw the multi-adapter (27) onto the pump
connection (6). Hoses with dimensions
can be attached to the multi-adapter.
6.5
Mounting tap connector (28)
Screw tap connector (28) onto the pump connection
(6).
6.6
Mounting hose (19)
The hose can be connected with the quick coupling
(21) to the tap connector (28).
12
7. Use
7.1
Control panel (8) see overview p. 3
1. Activation button:
Briefly pressing the ON/OFF (10) button starts the
pump at the last selected power setting.
2. Change power setting:
Briefly pressing the (11) button switches between
the three power settings (1., 2., 3., back to 1.). The
respective setting is shown by the three green
LEDs.
Power setting 1: max 1,200l/h, max. 0.6bar
Suitable for: Watering with garden sprinkler, light
cleaning work, use of short hoses
Power setting 2: max 1800 l/h, max. 1.3bar
Suitable for: Irrigation (garden sprinkler)
Power setting 3: max 2200 l/h, max. 2.2bar
Suitable for: Drainage with long hoses, garden
irrigation with surface sprinklers
3. Timer function:
Timer function (LED blue)
The pump has a selectable timer function, e.g. for
targeted use of garden sprinklers.
During the operation of the pump, the automatic
timer function can be selected after 5/10/20 minutes
by briefly pressing the button (3.) (blue LED active).
Pressing for the fourth time deactivates this
function. During the timer function, the power
setting can be changed as desired. The LED
display changes back to the timer function (blue)
after selecting the power setting (green).
The pump switches off automatically after the
selected time has elapsed. By pressing the ON/
OFF button (1), the timer function can be cancelled.
The timer function must be reactivated each time
the unit is started.
4. Status LED battery pack (13)
Shows the charge level of the battery pack.
5. LED fault display (9)
Dry-running protection: The LED (E) flashes red if
the pump cannot convey water after 15 seconds.
Putting the pump back into operation: Briefly press
ON/OFF (10) button.
7.2
Pump water from container
The pump must not touch the container base. This
keeps dirt in the container away from the pump.
3
The pump should hang approx. 10 cm above the
/
" and 1"
4
container bottom to prevent excessive
contamination.
1. Hang the battery box (7) on the outside on the
side of the container or place it in a suitable, flood-
proof location.
2. Lower the pump with a rope or the supplied hose
guide into the container (do not hang it from the
cable).
The position of the pump can be varied by moving
the hose in the hose guide.
3. Start the pump.