en
ENGLISH
-Low water level
Check water level, completely immerse pump in
water.
10. Maintenance
Remove the battery pack before each
maintenance.
11. Transport
Remove the battery pack for transport and secure
pump against impact.
Secure cable using cable storage (3) on the back of
the pump housing (4)
12. Storage
Remove the battery pack and turn pump upside
down so that any residual water can flow out.
Store the pump and battery pack in a closed, dry
place, protected from frost and out of the reach of
children.
f
13. Accessories
Use only original Metabo or CAS (Cordless Alliance
System) battery packs and accessories.
A Chargers: ASC 55, ASC 145, etc.
Order no.: 627044000ASC 55
Order no.: 627378000ASC 145
etc.
B Battery packs:
Order no.: 625026000 2.0 Ah (Li-Power)
Order no.: 625027000 4.0 Ah (Li-Power)
Order no.: 625369000 8.0 Ah (LiHD)
etc.
For a complete range of accessories, see
www.metabo.com or the catalogue.
14. Repairs
Repairs must be carried out by qualified
electricians only!
If you have Metabo devices that require repairs,
please contact your Metabo service centre. For
addresses see www.metabo.com.
You can download a list of spare parts from
www.metabo.com.
15. Environmental Protection
Observe national regulations on environmentally
compatible disposal and on the recycling of disused
machines, packaging and accessories.
Packaging materials must be disposed of according
to their labelling in accordance with municipal
guidelines. Further information can be found at
www.metabo.com in the "Service" section.
14
Battery packs must not be disposed of with regular
waste! Please return faulty or used battery packs to
your Metabo dealer!
Do not throw battery packs into water.
Only for EU countries: never dispose of
power tools in your household waste!
According to European Directive 2012/19/EU
on Waste from Electric and Electronic Equipment
and implementation in national law, used power
tools must be collected separately and recycled in
an environmentally-friendly manner.
Discharge the battery pack in the power tool before
disposal. Prevent the contacts from short-circuiting
(e.g. by protecting them with adhesive tape).
16. Technical specifications
Explanatory notes on the specifications on page 3.
Subject to change in accordance with technical
progress.
U
= Voltage of battery pack
FM
= Delivery rate max
max
FH
= Delivery head max
max
FD
= Delivery pressure max
max
E
= Immersion depth max.
max
A
= min. intake height
min
R
= Residual water level max.
max
K
= Particle size max.
max
T
= Temperature max. pumping medium
max
IP
= Protection class of pump
P
IP
= Protection class of box
B
K
= Cable length box-pump
BP
D
= Pressure connection
m
= Weight
A
= Overall dimensions (lxwxh)
ges
A
= Dimensions without stand (lxwxh)
OS
A
= Dimensions of battery pack box (lxwxh)
AB
Permitted ambient temperature for storage and
when the pump is in operation:
3 °C to 35 °C.
Details on the temperatures for the battery pack can
be found in the operating instructions of the battery
pack.
direct current
The technical specifications quoted are subject to
tolerances (in compliance with the relevant valid
standards).