Information on maintenance and care
Clean all components with a damp cloth and do not use cleaning agents,
scouring agents and solvents. Remove the battery(ies) before storing
for longer periods. Store the device in a clean and dry place.
Calibration
The meter needs to be calibrated and tested on a regular basis to ensure
it produces accurate measurement results. We recommend carrying out
calibration once a year.
Technical Data
Precision (typical)*
Measurement range
(inside)**
Laser class
Laser wavelength
Operating conditions
Storage conditions
Automatic switch-off
Power supply
Dimensions (W x H x D)
Weight
* measuring distance up to 10 m with strongly reflective target surface and at room temperature.
The measurement deviation may increase by +/-0.2 mm/m for weakly reflective target surfaces.
** at max. 5000 lux
EU directives and disposal
This device complies with all necessary standards
for the free movement of goods within the EU.
This product is an electric device and must be
collected separately for disposal according to
the European Directive on waste electrical and
electronic equipment.
Further safety and supplementary notices at:
http://laserliner.com/info?an=ACF
DistanceMaster Compact
(Subject to technical changes without notice. Rev21W31)
± 2 mm
0,1 m - 25 m
2 / < 1 mW (EN 60825-1:2014/AC:2017)
650 nm
-10°C ... 40°C, max. humidity 80% rH,
no condensation, max. working altitude
2000 m above sea level
-20°C ... 70°C, max. humidity 80% rH
30 sec laser / 3 min device
2 x 1,5V LR03 (AAA)
27 x 110 x 43 mm
100 g (incl. batteries)