any possible traces of humidity on the parts of the room with wood or paper etc. To minimise these effects, it is
recommended to air the room in which it is installed (extractor fan or extraction system).
INSTALLATION OUTSIDE/ON TERRACE
The foundations must be solid. Find out the load capacity of the intended surface and call a qualified tradesman or a
construction engineer. To know the weight of the spa while empty and full, refer to the specifications table. The weight by
m2 must not exceed the nominal capacity of the structure to avoid causing serious damage to the structure. If you install
the spa outside, we recommend that you place it on a concrete slab of a thickness of at least 10cm. Do not forget to
install the ground siphons around the spa to be able to drain water in case of heavy rain.
WARNING: You must fix the tarpaulin to your spa and for strong wind, you will have to ballast it.
PREPARATION FOR CONNECTION TO THE MAINS
Make sure that the 30mA circuit breaker is permanently connected (electric board of YOUR installation) to a circuit
protected by a switch in case of an earth fault. Only use copper cables. The electrical connection of the spa is very
important as when it is running at full power, it consumes a high level of amps. The first step is to calculate the maximum
current supported by the 230 volts line.
The electrical connection must be done by a professional and in accordance with current standards (cable
section/ power of the circuit-breakers and adequate protection)
Description of use:
How to use the filtration system:
1. Install the filter: open the handle lock of the filter lid, remove the cover and put the filter in place, then replace
the cover and the handle lock.
2. To replace the filter: open the filter cap handle lock, remove the cover and then take out the filter. Remove the
dirt from the bottom of the filter, then replace the clean filter. Next replace the cover and the handle lock.
3. Clean the Filter: the base filter can be directly rinsed with pressurised water, or shake it after it has been dried.
4. When you use the filter for the first time, open the escape valve on the upper lid of the filter to ease the
pressure after having poured enough water into the spa;
Use of ozone generators:
5. Disinfection takes on average between 15 and 20 minutes.
Maintenance access II
from the water pump 1 and the jets
Maintenance access
IV (Air pump)
Maintenance access III
(Electrics and filter box)
Control panel
Maintenance access I (water pump 1 and jets) connected with the water channel