To examine the battery and the battery
charger
1. Examine the battery for damages, for example
cracks.
User interface Aspire P5-P4A
Problem
Possible faults
Green start LED
Low battery voltage.
flashes.
Red error LED
Overload.
flashes.
Temperature deviation.
The power trigger and the start button are
pushed at the same time.
Green LED and red
The battery is empty.
LED flash alternately.
The battery is damaged.
Troubleshooting of the battery charger
LED on the battery
Cause
charger
The green LED is
The battery is not correctly
on and the red LED
installed in the battery charger.
flashes.
The battery connectors are dirty.
The ambient temperature is too
high or too low.
The battery is defective.
The green LED and
The battery charger is not
the red LED are off.
correctly connected to the mains
outlet.
Faulty mains outlet.
The battery charger cable is
defective.
The battery charger is defective.
406
2. Examine the battery charger for damages, for
example cracks.
3. Make sure that the connection cord of the battery
charger is not damaged and that there are no cracks
in it.
Troubleshooting
Possible solution
Charge the battery.
The cutting attachment is blocked. stop the
product. Remove the battery. Clean the
cutting attachment from unwanted materials.
Loosen the chain.
Let the product become cool.
Release the power trigger and push the start
button.
Charge the battery.
Speak to your servicing agent.
Solution
Remove the battery from the charger and install the
battery in the battery charger again.
Clean the battery connectors.
Use the battery charger in temperatures between 0 °C –
+35 °C.
Replace the battery.
Connect the battery charger to a mains outlet.
Connect the battery charger to the voltage and frequency
that is specified on the rating plate.
Speak to an approved service agent.
1867 - 004 - 19.09.2022