GAS COUPLING
- Connect a pressure regulator to the gas bottle. Connect the welding machine (fig. F) using the pipes supplied, and place the two
clamps to avoid leakages.
- Set the gas flow by adjusting the dial located on the pressure regulator.
NB : to help facilitate the adjustment of the gas flow, operate the drive rollers by pressing the trigger of the torch (ensure that the
drive roller is completely loose so the wire is not fed through).
This procedure does not apply to «Gasless» welding mode.
RECOMMENDED COMBINATIONS
(mm)
0.8-2
2-4
0.6-1.5
1.5-3
RISK OF INJURY DUE TO MOVING PARTS
The wire feeders contain moving parts that may catch hand, hair, clothes or tools which can lead to injuries! Take extra
care.
• Do not lay a hand to swivel or moving components or parts to the drive!
• Ensure that the housing covers or protective covers remain closed during operation!
• Do not wear gloves when threading the filler wire and changing the filler wire spool.
ADVICE & THERMAL PROTECTION
This device is equipped with a ventilator regulated by the inside temperature. When the machine's thermal protection is activated, it
will not deliver any current. Orange light (Fig-V-2) will turn on until the temperature of the machine has returned to normal.
• Do not block/cover the ventillation holes, ensure free flow of air.
• Whilst in thermal protection mode leave the machine plugged into the mains after welding to allow it to cool.
General observations :
• Always respect the basic rules of welding.
• Always work in an adequately ventillated area.
• Do not work on a damp surface.
TROUBLESHOOTING
SYMPTOMS
The welding wire speed is not
constant.
The wire-feeder motor doesn't
operate.
Bad wire feeding.
No welding current
The wire jams (after the rollers)
16
EASYMIG 110-130-140-150
Current (A)
Ø Wire (mm)
20-100
100-200
15-80
80-150
POSSIBLE CAUSES
Debris is blocking up the opening.
The wire skids in the rollers.
Reel or roller brake too tight.
Electrical supply problem.
Covering wire guide dirty or damaged.
The drive roller is too loose
Reel brake too tight
Bad connection to the main supply.
Bad earth connection.
Torch trigger inoperative.
Guide wire sheath crushed.
Wire jammed in the torch
No capillary tube.
Wire speed too fast
Ø Nozzle (mm)
0.8
12
1.0
12-15
0.6
12
0.8
12-15
Clean out the contact batch or change it and replace
the anti-adherence product.
Ref.041806.
• Control the roller pressure or replace it.
• Wire diameter non-compatible with roller
• Covering wire guide in the torch non-compatible.
Release the brake and rollers.
Check that the power switch is in the "On" position.
Clean or replace
Tighten the drive roller knob
Release the brake
Check the mains connection and look if the plug is fed
by 230 V (1PH) power socket.
Check the earth cable (connection and clamp condi-
tion).
Check the torch trigger / replace torch
Check the sheath and torch body.
Clean or replace.
Check the presence of capillary tube.
Reduce the wire speed
EN
Flow rate L/min
10-12
12-15
8-10
10-12
REMEDIES