The weighing modules have been primarily designed for use in tank weighing. As a rule,
the weighing modules are equipped with adjustable limit stops that limit horizontal move
ments, for example by wind forces or in mixer operation. In addition, the modules are
provided with a anti‐liftoff device which prevents the tank from lifting off. However, en
sure that the specified data (see chapter 7 on page 21) are not exceeded.
The modules comprise a lower module plate for mounting on the basic construction
(foundations), a load cell dummy with load introduction elements and the upper module
plate for tank mounting. For load introduction into the load cell, a rubber‐metal bearing
(with RTN/M2LA) or a pendulum bearing (with RTN/M2LB) is used which allows for
horizontal shifting of the load applied. The weighing modules are completely fitted with a
load cell dummy that can be loaded, with a ground cable, and a securing device for
transport.
RTN/M2
7
GENERAL