Safety notes
Prevent danger resulting from damaged voltage
supply cables.
If damaged, the voltage supply cable must be
replaced by the manufacturer or his customer service
department or an equally qualified person.
• Installation is only possible in frost-free rooms.
• The plug-in voltage supply is only suitable for indoor use.
• The plug-in connectors must not be directly or indirectly
sprayed with water when cleaning.
• The voltage supply must be separately switchable.
• Use only genuine replacement parts and accessories.
The use of other parts will result in voiding of the warranty
and the CE identification, and could lead to injuries.
Operating conditions
®
version 4.0.
Bluetooth
The current version of the app required for using the system
must be installed on the control unit in advance.
The required App is available for free in the iTunes Store
(requires an Apple account) and the Google Play store
(requires a Google account), see fold-out page I.
For operation under adverse environments, in buildings /
rooms with reinforced concrete walls, steel and iron frame, or
near of obstructions (eg furniture) of metal, the Bluetooth
reception can be disturbed and interrupted.
Type of obstructions
Wood, Synthetic material,
glass
Water, Bricks, Marble
Plaster, concrete, solid wood
Metal
The transceiver operates in the ISM-frequency range
(2.4GHz). The installation in the vicinity of equipment with the
same channel occupancy should be avoided.
In cases of malfunktions, turn off the source of interference
shortly.
Technical data
Fitting with switched-mode power supply:
• Voltage supply:
• Power consumption:
Fitting with battery:
• Voltage supply:
®
Bluetooth
:
• Power consumption:
• Output:
®
• Bluetooth
- version:
® -
• Bluetooth
Transmission distance:
(depending on the environments)
3
Interference or shielding
potential
Low
Medium
High
Very high
100-240 V AC 50-60 Hz/6.75 V DC
6V lithium battery type CR-P2
®
Bluetooth
about 10m
• Automatic safety shut-off:
(6 - 420 s adjustable)
• Run-on time (0 - 19 s adjustable):
• Reception range according to
Novoflex Zebra XL Grey Card,
grey side, 8x10", landscape:
• Type of fitting protection:
Thermal disinfection possible.
Electrical test data
• Software class
• Contamination class
• Rated surge voltage
• Temperature of ball impact test
The test for electromagnetic compatibility (interference emission
test) was performed at the rated voltage and rated current.
If static pressures exceed 0.5 MPa, a pressure-reducing valve
must be installed.
Avoid major pressure differences between hot and cold water
supply!
Installation
Flush pipes thoroughly before and after
installation (observe EN 806)!
Open hot and cold water supply and check that
connections are watertight.
Setting temperature limiter,
see fold-out page II.
Operation and settings,
see technical product information, 99.0409.xxx /
99.0438.xxx
Activating setting mode
Disconnect the power supply to the electronics and reconnect
after 10 s.
The indicator lamp in the sensor system illuminates in setting
mode when the detection zone of the fitting is reached by an
approaching user.
Setting mode is automatically terminated after 3 minutes..
2.4 W
Maintenance
• Shut off hot and cold water supply.
• Disconnect voltage supply.
• Inspect and clean all components and replace if
1 W
necessary.
- Class 2
4.0
Batteries which are almost discharged are displayed
by a flashing indicator lamp in the sensor system.
20cm
, see fold-out page II.
, see fold-out page III and IV.
60 s
1 s
12cm
IP 59
A
2
2500 V
100 °C