Sullair SR 250 Manual De Uso página 108

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

English -- Legend
LABELS
a
S Model
S Serial No.
S Low/High side refrigeration
circuit design pressure
S Max air pressure
S Max compressed air inlet
S Min. ambient
Max ambient
S Power supply
Electrical diagram no.
S Oil
S Min. circuit ampacity
S Max protective device rating
S Compressor
S Fan 1
S Fan 2
S Max cooling water pressure
S Min. cooling water pressure
S Refrigerant
S Weight
b
QUALITY CHECKED INSPECTOR N. 302
c.
See Chapter 2
d. Air inlet
e.
Air outlet
d1. Water inlet
e1. Water outlet
f.
ATTENTION: components under power.
g.
ATTENTION: SCHRADER VALVE
1 This unit is equipped with refrigerant as for quantity and kind clearly shown
in operating manual and with identification label.
2 Any ordinary test and / or refrigerant recharge by means of connections can
take place only after refrigerant evacuation. The evacuation must be pro-
portional to dimensions and length of the connections used. The use of the
valve can be justified only when the dryer is not in working order.
3 During the unit guarantee period, the Schrader valve can be used by autho-
rized staff only, otherwise any damage caused by a wrong refrigerant
recharge will not be under warranty.
l.
Condensate drain connection
Code: 02250145- - 604 SR- - 250 --- SR- - 3000
All manuals and user guides at all-guides.com
m. ATTENTION!
Never pass compressed air through the dryer when it is stopped.
Always start the dryer 5 minutes before slowly opening the air
inlet valve. If the airflow is to bestopped only switch the dryer
off after closing the air inlet.
n. SETTING (hot gas valve)
Evaporating pressure in 0_C, with precision manometer con-
nected at evaporator outlet.
o. ATTENTION: SCROLL three---phase compressors.
If the compressor is noisy and the pressure on the (LP) gauge
does not decrease you should immediately invert two phases.
Please refer to the service manual for more details.
p. ATTENTION: Hot and moving parts enclosed, disconnect the
mains supply before removing this cover.
q. ATTENTION
1 Fully drain the piping before connecting this unit to the exter-
nal water piping (cold water, make up water, ect.).
2 Fitting of a standard strainer is also strongly recommended
on the inlet water piping.
r. WARNING:
Risk of electric shock can cause injury or death.
Disconnect all remote electric power supplies before servicing.
s. BSPP pipe threads
use supplied adapters
DRAWINGS
A. TIMED SOLENOID DRAIN
1. MC
compressor
2.
refrigerant condenser
3. EV- - 1- - 2 fan motor
4.
evaporator
5.
separator
6.
insulation
7.
expansion capillary
8.
refrigerant filter
9.
hot gas valve
10.
air ---air heat exchanger
12. PV
fan pressure switch
14. QS
main switch
15. HP
high pressure switch
16. ST
high temperature thermostat
17.
low pressure manometer
18.
compressor valve
25.
thermometer sensor pocket
27.
gas charge point
28.
water pressostatic valve
29.
high pressure tap
30. QF1
compressor motor automatic switch
30a QF2
fan motor automatic switch
31. KM2
fan motor contactor
32. KM1
compressor motor contactor
33. TC1
auxiliary transformer
35.
power cable inlet
36.
remote control cable entry point
37.
control panel
38. T0
dew point temperature sensor
40.
liquid separator
FU1- - 2 transformer fuse TC1
FU3- - 4 auxiliary fuse 230V
FU5
control panel fuse
PI
compressor internal protection
KA1
high pressure alarm relay
C1
compressor start capacitor
C2
fan run capacitor
QF
residual current circuit---breaker
(by installer)
(A)
remove bridge if "remote on---off"
is installed
107