Note: The appliance must not be cemented in its enclosure under any circumstances, sufficient space
should be left to expand and contract freely, typically between 2 and 5 mm around its perimeter. It is
advisable to connect at least one of the 4 hot air outlets of the appliance.
When installing the appliance, all local regulations, including those relating to
National and European standards, must be followed.
The chimney cap should not have an obstruction to the outside
air currents, i.e., it should allow the air entering through the side
ports to exit the opposite side without causing descending air
currents.
The recommended dimensions for the smoke outlets of the
appliance are defined in the technical data table pg, 6. As you
can see, the correct installation of the chimney is therefore one of
the fundamental aspects to obtain the desirable yield of your
appliance and is, due to its technical nature subject to several
specific standards that must be taken into account and obeyed.
It is necessary to provide accessibility for maintenance of the
piping, so the piping fixation should not be permanent.
The chimney shall be at least 0.6m above the ridge, in any area
other than the ridge shall be at least 1m above the roof. Your
chimney should be cleaned at least once per season