Technical assistance

If you comply with the instructions given in this manual, you should not have any
major problem in enjoying the fullness of your appliance. However, before
requesting service, check if:
1. All the instructions given in this manual are complied with.
2. If there has been any recent change in the periphery that may have given rise to the problem.
3. If the problem falls into the following points.
Problem (s)
The appliance is
smoking
Weak or inefficient burn
Very fast burning
The fire extinguishes
Blower not working
Dirty glass
If the problem persists, then contact us through our agents or directly to have our helpdesk help you resolve
the problem.
Possible Cause
Closed smoke output regulation (when
applied)
Wet or green firewood.
Dirty or clogged chimney.
Wet or green firewood.
Dirty or clogged chimney.
Insufficient firewood.
Low density firewood.
Poorly adjusted door
Filling cord consumed
Wet or green firewood.
The appliance is not heated enough.
The thermostat's operating temperature
has not been reached
Power failure
Wet or green firewood.
Open smoke output control
Use drier wood.
Clean the chimney.
Use dry wood.
Clean the chimney.
Load the stove with more dense firewood.
Door readjustment
Replacement of the cord
Use drier wood.
Heat the appliance well by opening the main air
regulator.
Load more firewood
Check outlets and connections
Slightly open the air inlet control
Use dry wood.
32
Correction