Before use

Selecting the grinding disc

Metal Removal and Surface:
The rate of metal removal and the surface quality
are determined by the grain size of the grinding
disc.
Lease note that corresponding grinding discs
with different grain sizes should be used for
processing different materials.

Changing sanding sheets

The air sander is fitted with a hook and loop faste-
ning, which allows for quick and easy replacement
of sanding discs.
Lift the grinding disc at the side and pull it off
from the backing pad
HINWEIS
Before securing a new sanding sheet, remove
all dust and dirt from the sander plate
Ensure that the openings in the sanding sheet
concur with the boreholes of the sanding plate

Dust / swarf removal by suction

WARNING!
Please note the "Safety instructions" section.
Using the internal vacuum extraction with
dust collection device (see Fig. B):
Push the exhaust air hose
connection for dust extraction
You have to evert the opening of the dust bag
first, so that the straps are outside. Put the
opening of the dust bag
the exhaust air hose
firmly in position. In this way, the dust bag
can be tied tightly to the exhaust air hose
NOTE
Empty the dust bag
gularly to ensure optimum dust extraction. To
do this open the zip fastener on the underside
of the dust bag
PDEXS 150 D3
in order to remove it.
fully on to the
.
over the free end of
and fasten the dust bag
in good time and re-
.

Topping up the oil

In order for the air sander to have a long service
life, there must always be enough pneumatic oil in
the device.
HINWEIS
Use safe lubricants.
When determining which lubricants to use,
you must consider the environmental, occupa-
tional, and health aspects involved.
You may ensure this in any of the following
ways:
Connect a service unit with an oiler to the
compressor.
Install a line oiler in the compressed air line or
at the compressed air device.
Put approx. 3–5 drops of pneumatic oil by
hand into the plug nipple
of operation.
.

Preparing for use

.

Connecting the compressed air source

NOTE
The air sander must be operated using
cleaned and condensate-free compressed
air only and its maximum allowable working
pressure of 6.3 bar at the device must not be
exceeded.
The compressed air source must be fitted
with a (filter) pressure reducer so that the air
pressure can be regulated.
Connect the plug nipple
coupler to the compressed air supply.
.
every 15 minutes
by a quick-release
GB │ IE