7) OPERATION

Before usage, always check the dispenser for any
visible signs of damage and faults. Only use the
dispenser when it is in usable condition. If you are
unsure of the usability of the device or if signs of
breakage or other damage become recognizable, stop
using the device immediately. Send the device to an
authorized agent of the manufacturer for inspection and
repair (refer to the address list at the back). Check the
outlet of the cartridge and the mixer (15) for obstruction
(e.g. hardened materials) before dispensing.
If working at height, it is recommended to
connect the dispenser to an appropriate tool
restraint lanyard via the connection eye (11).

Controls

The dispenser is activated when the trigger (1) is actu-
ated. The trigger has the following variable settings:
• Variable speed control: Dispensing output speed
can be regulated by gradually (variable trigger)
pressing the trigger.
• Dripping protection: The plungers (5) are automati-
cally moved slightly backwards when the trigger (1)
is released
• Trigger lock (12): locks the trigger (1) to prevent ac-
cidental operation
• Release button (3): when pressed, plungers can be
manually moved, cartridge can then be released re-
spectively inserted
• Adjustment wheel (2): specifies the maximum speed
of the plungers when the trigger (1) is fully actuated.

Operating modes

Refer to figure {D} on page III:
• Trigger lock (12) pressed up: The trigger (1) is
locked
• Trigger lock (12) pressed down, prepared cartridge
inserted, trigger (1) actuated: dispenser works with
the adjusted speed (2)
EN

Inserting the cartridge

i
WARNING Risk of injury if the wrong
cartridges are used or used incorrectly,
bursting cartridges!
Use the cartridges in accordance with the force of

the dispenser, see " Type plate and CE mark" on page 2
and see "10) Technical data" on page 11.
Observe the safety instructions on the cartridge

i
CAUTION Risk of crushing by extend-
ing plunger!
When inserting the cartridge, do not put

your fingers in the insertion area!
Refer to figure {C} on page III
MR only:
1. Insert cartridge into the cartridge holder (7). When
using mixed ratio cartridges pay attention to orienta-
tion, ensuring smaller cartridge cylinder is inserted first
into the holder.
2. Press cartridge until cartridge cylinders locate posi-
tively into it corresponding profile of cartridge straps
(13).
600 1:1/ Extended:
1. Align rear or cartridge cylinders into corresponding
cartridge locators (14).
2. Using aligned cartridge depress locators rearward
and simultaneously push cartridge down to sit hori-
zontally in cartridge holder (7). Ensure outlet nozzle
of cartridge is correctly located into cutout in front
plate (4).