8) TROUBLESHOOTING
No. Fault
The dispenser does not
1
work when the trigger is
being pressed
It was not possible to ac-
2
tuate the trigger
The plungers (5) are
3
moved back when the
trigger (1) is actuated
The plungers (5) are
4
moved forwards but no
material is discharged
It was not possible to re-
5
tract the rack (8)
EN
Cause
• No battery
• No battery charge
• Trigger lock (12) is activated
• End stop is reached
• Adjustment wheel on zero
• Release button (3) is activated
• Trigger lock (12) is activated
For safety reasons the dispenser has a
power limiter so that the cartridge and
the cartridge holder are not damaged
The cartridge is damaged
• Release button (3) is not activated
or fully pressed
• Counterpressure on pistons
10 of 12
Remedy
• Insert the battery
• Check the battery charge, charge if
necessary
• Turn adjustment wheel into another
position
• Deactivate trigger lock (12)
• Deactivate release button (3)
• Deactivate trigger lock (12)
• Check the cartridge/mixer (15) for
obstruction
• Check the temperature of the car-
tridge
• Lower the dispensing speed
• Stop discharge and remove the car-
tridge
• Clean the dispenser
• Press release button (3) fully
• Quickly tip trigger to perform anti-
drip movement several times
Instruction handbook ElectraFlow
Dual Ultra · Version 1.3 · 9.4.21