Air intake connection
• Connect the air hose to the tool using a female fast
connector (A) (not included). When working with
different pneumatic tools and a single compressor, you
can quickly connect and disconnect tools exchange them
easily.
• Before starting to work, run the tool 30 seconds
unloaded and in a safe position. Stop immediately if
detecting any defect in installation.
Turning On
• Turn on the air compressor and let it fill up.
• Regulate the air compressor output pressure from 621 to
793 kPa (90 to 115 PSI).
WARNING
Operating the tool above this pressure
range will result in a shorter tool life.
• Check the work piece is sagely fastened.
• Push the trigger lock (B) forward and press the trigger (C).
Wait for the tool to reach its maximum speed before making
contact with the workpiece. When you are done roughing
up, remove the tool from the work piece before turning it
OFF.
• Do not apply excessive force upon the tool. This
decreases the speed and efficiency of the cut as well as
discharging the tool by decreasing its life time.
CAUTION
• Double check the sparks produced by the
cuts will not turn into a dangerous situation.
Lubrication
• Pneumatic tools need constant lubrication along their
useful life and during the operation. The compressed air
needed in the tool to run carry humidity which could
oxidize the motor and bearing in the tool. To prevent this
possibility, it is necessary to constantly deliver lubricating
oil through a
centralized filter-oiler system installed between the air
compressor and the tool.
• Any excess of oil in the motor is
WARNING
immediately expelled through the exceeding oil escape.
Keep the escape free of obstructions and never point it
towards people or objects.
• If not using the tool for long periods of time, it shall need
to be lubricated with care.
• After 60 hours' operation, the tool mechanism need a
little greasing. Excessive grease may diminish power.
8
ENGLISH

Maintenance

Brand UNI-LL-1/4

Start Up

Air Hose
A
D
• Using a screwdriver, turn the regulating screw (D)
to control the air flow into the tool to adjust the
speed of the accessory.
Service
• Servicing the tool shall be carried out every 3 months
only in a
Service and maintenance carried out by not certified
people mat y be dangerous and can cause severe
personal injuries as well as making the product Warranty
void.
• Malfunction in the tool caused by no using the
recommended dose of lubrication, or not complying
with this Instructions, or repairs carried out by people
not certified by
with the Warranty. We reserve the right to carry out
technical improvements without notice.
Fast Connector
(not included)
Air
Intake
C
B
Authorized Service Center.
will not be covered