Function
Parameter1
TALKBACK/
OSCILLATOR
Screen
METER
Talkback
ON/OFF
Monitor Source Select
Monitor Select 1-6
MUTE
Monitor Control
DIM
CH 1-40
ST IN 1-2
SEND ON/OFF
FX RTN 1-4
MIX 1-22
MAIN L/R
NOTE
i Foot Switch: GPIO-IN:
• When Mute Group, Talkback, Monitor Control and SEND ON/OFF functions are assigned, the selected function will be activated
while a Low level signal is being input. Moreover, if the same function is assigned to multiple GPIO-IN and/or footswitches, the
function will be activated when any one of those signals is Low level. The function will be deactivated only when all the signals
from the assigned GPIO-IN and/or footswitches are High level (OR operation).
• When other functions are assigned, the selected function will operate if a Low level signal of 50 ms or longer is input.
i Snapshots stored with this function are named "USER KEY" followed by a three-digit slot number (for example, "USER KEY 018").
i When the Function is set to Snapshot and Parameter 2 is set to No, if Parameter 3 matches the current Snapshot number, the
corresponding USER KEY will light.
GPIO-OUT page
Function
Parameter1
CH 1-40
ST IN 1-2
Fader Start
FX RTN 1-4
MIX 1-22
MAIN L/R
CH 1-40
ST IN 1-2
Fader Stop
FX RTN 1-4
MIX 1-22
MAIN L/R
CH 1-40
ST IN 1-2
Fader Start/Stop
FX RTN 1-4
MIX 1-22
MAIN L/R
18
TASCAM Sonicview 16XP/Sonicview 24XP
Parameter2
Parameter3
ALL LAYER
OUTPUT
LAYER1-7
LAST TAB
MIX 1-22
FX 1-4
Parameter2
Parameter3
Function explanation
Show the TALKBACK/OSCILLATOR page of
the MONITOR SETUP Screen on the rightmost
touchscreen and light the corresponding USER KEY.
When this screen is open, pressing a corresponding
USER KEY will close it.
Show the page of the METER Screen specified by
Parameter 2 on the rightmost touchscreen and light
the corresponding USER KEY. When this screen is
open, pressing a corresponding USER KEY will close it.
Turn the talkback mic on/off.
Select a specific number for Monitor Select.
Turn monitoring signal muting on/off.
Turn monitoring signal dimming on/off.
This turns ON/OFF the SEND from the module
specified with Parameter 1 to the bus specified with
Parameter 2.
The key will light when this setting is on.
Function explanation
A pulse signal will be output when the status of the
specified module becomes as follows (Active Low/150ms
pulse width).
o When MUTE is off and the FADER level changes from
below to above the fader start level setting value
o When the FADER level is above the fader start level
setting value, and MUTE changes from on to off
A pulse signal will be output when the status of the
specified module becomes as follows (Active Low/150ms
pulse width).
o When MUTE is off, and the FADER level changes from
above to below the fader start level setting value
o When the FADER level is above the fader start level
setting value and MUTE changes from off to on
When MUTE is off for the specified module and the FADER
level is above the fader start level setting value, LOW level
signal output will be latched.