T R O U B L E S H O O T I N G
Er01: indicates abnormal communication between electronic watch and electronic control
The console wire is not connected properly
Er02: indicates abnormal indication of voltage no. between the down control and motor
The motor wire is not connected properly
Er03: indicates the indication of speed anomaly detected by down-control
PWM drive circuit on the down control board failure
Er04: indicates the overvoltage protection information of the down control.
The input voltage of the treadmill exceeds the rated operating voltage of the motor.
E05: indicates that the driving power voltage is too high and an abnormal phenomenon is indicated
The input voltage of the treadmill exceeds the rated operating voltage of the motor.
E06: indicates that the driving power voltage of the lower control no. is too low and an abnormal
phenomenon is indicated
The supply voltage is too low
E07 : indication that the console security lock is not connected properly
The magnetic safety key is not attached properly.
//