Programming
To enter programming mode, a connection must be made between the programme input and the
negative (–). The LED will blink once if the connection has been maintained for ± 2 seconds. Once
this is done, the connection must be broken.
The same connection must be made briefly again to set the correct position number—the LED will
light up as feedback.
At that point, programme position #1 is selected. The user can briefly make the connection again to
select programme position #2, etc., etc..
If no connection is made for ± 4 seconds, the LED will display the set state again. (Example:
programme position #4 is set by a user, the LED will blink 4 times)
Two types of settings are available. Positions 1 through 10 set the undervoltage threshold and reset
values. Positions 11 and 12 set the overvoltage threshold and reset values. These settings must be
selected individually.
The programmed positions are retained when the battery voltage is disconnected.
Technical data
ELECTRICAL
Input voltage range
Maximum continuous output current (@25
°C)
Peak current (@25 °C)
Voltage drop
Current consumption
Output active
(@12 V)
Output inactive
Voltage accuracy
Current accuracy
Maximum alarm output load
INPUT & OUTPUT CONNECTION
Minimum conductor gauge
Bolt size
Cable lugs
FASTON CONNECTIONS
Minimum conductor gauge
Faston plug
BGM200 [ARF200905]
6 ... 35 V
200 A
1.200 A (±0.7 sec)
50 mV @ 200 A
3.2 mA
3.2 mA
2%
10%
100 mA
2
50 mm
M8
Cable lugs must match the
cable diameter used.
2
1.5 mm
6.3 mm
0773459
Programming table
Position
1*
2
3
4
5
6
7
8
9
10
11*
12
* → Factory default.
MECHANICAL
Mounting hole (Ø)
Distance between mounting holes (centre
to centre)
Weight
Dimensions (H*L*W)
IP Code
Housing material
Housing colour
Cooling concept
GENERAL
Operational ambient temperature
Storage temperature
Operational air humidity
Galvanic insulation
Remote contact switch-off
PROTECTION
Overcurrent / Short circuit
Overheating, shutdown
Polarity protection
12V
24V
UNDERVOLTAGE (V)
Threshold Reset
Threshold Reset
10.5
12
21
10
11.5
20
9.5
11.5
19
11.25
13.25
22.5
11.5
13.8
23
10,5
12.8
21
11.5
12.8
23
11.8
12.8
23.6
12
13
24
10
13.2
20
OVERVOLTAGE (V)
Threshold Reset
Threshold Reset
16
15.8
32
15.4
15.2
30.8
4.5 mm
100.0 mm
295 g
75.90*39,00*110.51 mm
IP66
PU552
Black
Convection and
conduction
-10 °C ... +40 °C
-25 °C ... +85 °C
Up to 95%, non-
condensing.
No
Yes
Yes. (After 1 minute
restart)
Above 85 °C. (After 1
minute restart)
Yes, with fuse in the
negative (-) line.
EN_DE_ES_FR_NL – V2 – 230109
24
23
23
26.5
27.6
25.6
25.6
25.6
26
26.4
31.6
31.4