CycloVac HD Serie Manual De Instrucciones página 15

Publicidad

Idiomas disponibles

Idiomas disponibles

ProbleM
Decrease in suction
strength (cont.)
If none of these suggestions restore suction strength, contact
Troubleshooting
PossIble cause
Blocked hose
obstruction in the piping
system
your authorized service center.
troubleshooting
correctIve actIon
plug the handle end of
the hose into the suction
inlet, thus reversing the
suction in the hose.
cover the gap around
the handle, to ensure
suitable suction strength,
and ensure contact with
inlet contacts to start the
unit. this should clear
the hose
remove the screw from
the air intake connector,
to free the collector from
the piping system. Start
the system by plugging
the hose into a vacuum
inlet. By placing your
extended hand over the
air intake opening on
the collector, check the
suction strength on the
collector itself. If suction
strength is normal, the
obstruction is in the
piping system. If suction
strength is diminished
or completely absent,
have the unit and dust
collector checked by an
authorized service center.
15

Publicidad