Descargar Imprimir esta página

Olimpia splendid NEXYA S5 E CASSETTE Instrucciones Para El Uso Y El Mantenimiento página 74

Ocultar thumbs Ver también para NEXYA S5 E CASSETTE:

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 196
(B)
Refrigerant piping side
770mm / 30.3" (Suspension bolt)
830mm / 32.7"(Body)
900mm / 35.4"(Ceiling opening)
950mm / 37.4"(Panel)
CAUTION
The unit body should align perfectly with the
hole. Ensure that the unit and the hole are the
same size before moving on.
2.
(A)
Drill 4 holes 5cm (2") deep at the ceiling hook
positions in the internal ceiling. Be sure to hold
the drill at a 90° angle to the ceiling.
(B)
Drill 4 holes 12cm-15.5cm (4.7"-6.1") deep at the
ceiling hook positions in the internal ceiling. Be
sure to hold the drill at a 90° angle to the ceiling.
3. Using a hammer, insert the ceiling hooks into
the pre-drilled holes. Secure the bolt using the
included washers and nuts.
4. Install the four suspension bolts.
Page 24
5. Mount the indoor unit. You will need two
Drain hose side
(A)
NOTE: The bottom of the unit should be
10-18mm(0.4-0.7")(
(0.9")(Compact models) higher than the
ceiling board. Generally, L (indicated in the
following figure) should be half the length
of the suspension bolt or long enough to
prevent the nuts from coming off.
Ceiling board
people to lift and secure it. Insert suspension
bolts into the unit' s hanging holes. Fasten
them using the included washers and nuts.
Classic models
Wall
L
10 - 18mm (0.4-0.7")
or 24mm (0.9")
) or 24mm
Main body

Publicidad

loading